Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology.
Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P < 0.001) and aortic arch (P = 0.004); vortex and helix flows were elevated for gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives.
BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology.
已知二叶式主动脉瓣(BAV)具有家族遗传性,且与主动脉病变及主动脉血流动力学改变有关。然而,BAV相关的主动脉病变是否能独立于瓣膜形态而遗传仍不清楚。
对24名具有三叶式主动脉瓣的BAV亲属(年龄 = 40 ± 14岁)和15名健康对照者(年龄 = 37 ± 10岁)进行了用于体内评估胸主动脉三维血流的四维血流磁共振成像。数据分析包括主动脉尺寸、形状(圆形/哥特式/立方体形)以及三维血流特征(半定量涡旋/螺旋分级和峰值流速)。与对照组相比,BAV亲属中立方体形和哥特式主动脉形状明显更为常见(38% 对 7%)。与对照组相比,BAV亲属升主动脉(AAo)的涡旋血流显著增加(分级 = 1.5 ± 1.0对0.6 ± 0.9,P = 0.015)。主动脉血流动力学受主动脉形状影响:哥特式主动脉的峰值流速低于圆形主动脉(P = 0.003);AAo中立方体形主动脉的涡旋血流增加(P < 0.001),主动脉弓中也是如此(P = 0.004);AAo和降主动脉中哥特式主动脉的涡旋和螺旋血流升高(P = 0.003,P = 0.029)。逻辑回归显示,在BAV亲属中,形状与AAo(P < 0.001)和主动脉弓(P = 0.016)的涡旋血流严重程度存在显著关联。
尽管没有瓣膜疾病或主动脉扩张,BAV亲属仍表现出主动脉形状改变和涡旋血流增加。这些数据表明,BAV相关的主动脉病变存在可遗传成分,其影响主动脉形状和异常血流,且独立于瓣膜形态。