Ahmad Nosheen, Shaukat Asim, Rehan Amna, Rashid Shamoona
Department of Radiology, PMC, Allied Hospital, Faisalabad.
J Coll Physicians Surg Pak. 2016 Jul;26(7):562-5.
To determine the diagnostic accuracy of perfusion computed tomography (PCT) in the grading of cerebral glioma.
Cross-sectional analytical study.
Department of Radiology, Allied Hospital, Faisalabad, from January to June 2014.
All the patients with untreated glioma had an initial non-contrast head CT and then PCT using 128 multidetector CTscanner. Perfusion maps of permeability surface (PS) and cerebral blood volume (CBV) were generated and measured. As control, a second volume of interest was placed in the contralateral healthy cortex. PCT parameters were compared with World Health Organization (WHO) glioma grades.
Fifty patients of 30 - 70 years of age of both genders (mean 45.13 ±5.54), 31 (62%) males and 19 (38%) females were studied. These patients were classified as low-grade glioma group (22 patients) and high-grade glioma group (28 patients). PS showed the sensitivity of 95.45%, specificity of 92.86% and diagnostic accuracy of 94% in differentiating the low-grade and high-grade glioma by using a cut-off value of 3.6 ml/100 g/minute. By using a cut-off value of CBV of 2.08 (ml/100 g) among low-grade and high-grade glioma group, CBV showed the sensitivity of 77.3%, specificity of 89.3%, and diagnostic accuracy of 84%.
The derived parameters (PS and CBV) correlate well with tumor histopathology, differentiating low-grade from high-grade gliomas. PS showed better accuracy for glioma grading.
确定灌注计算机断层扫描(PCT)在脑胶质瘤分级中的诊断准确性。
横断面分析研究。
2014年1月至6月,费萨拉巴德联合医院放射科。
所有未经治疗的胶质瘤患者均先行头颅平扫CT,然后使用128层螺旋CT扫描仪进行PCT检查。生成并测量通透性表面(PS)和脑血容量(CBV)的灌注图。作为对照,在对侧健康皮质放置第二个感兴趣区。将PCT参数与世界卫生组织(WHO)胶质瘤分级进行比较。
共研究了50例年龄在30 - 70岁之间的患者,男女均有(平均45.13±5.54岁),其中男性31例(62%),女性19例(38%)。这些患者被分为低级别胶质瘤组(22例)和高级别胶质瘤组(28例)。通过使用3.6 ml/100 g/分钟的临界值,PS在区分低级别和高级别胶质瘤时显示出95.45%的敏感性、92.86%的特异性和94%的诊断准确性。在低级别和高级别胶质瘤组中,通过使用2.08(ml/100 g)的CBV临界值,CBV显示出77.3%的敏感性、89.3%的特异性和84%的诊断准确性。
所获得的参数(PS和CBV)与肿瘤组织病理学相关性良好,可区分低级别和高级别胶质瘤。PS在胶质瘤分级方面显示出更好的准确性。