Park Hee Jin, Lee So Yeon, Rho Myung Ho, Chung Eun Chul, Kim Mi Sung, Kwon Heon Ju, Youn In Young
Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181, Korea.
Korean J Radiol. 2016 Sep-Oct;17(5):590-7. doi: 10.3348/kjr.2016.17.5.590. Epub 2016 Aug 23.
To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body.
A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated.
The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen.
The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.
比较在3T和1.5T场强下使用单次激发回波平面成像序列测量的表观扩散系数(ADC)值,以鉴别椎体良性骨折水肿和肿瘤浸润。
1.5T MRI组共纳入46例脊柱检查,3T MRI组共纳入40例脊柱检查。测量并计算病变的ADC值。评估包含矢状位T2加权脂肪抑制图像和不同b值ADC值的各扩散加权图像(DWI)的常规MR图像的诊断性能。
1.5T和3T场强下良性病变的平均ADC值均高于恶性病变(p < 0.05)。在1.5T和3T场强下,额外增加DWI时诊断性能的敏感性更高,但增加b值为400和1000时敏感性相似。诊断性能的特异性未显示出显著差异(p值> 0.05)。对于1.5T和3T场强,将任一DWI(b值为400和1000)添加到常规MR图像时诊断准确性更高。未观察到1.5T和3T场强之间或b值为400和1000之间的统计学差异。
1.5T和3T场强下良性病变的ADC值显著高于恶性病变。对于1.5T和3T场强,将任一DWI(b值为400和1000)添加到常规MR图像时,诊断性能无统计学显著差异。