Kerezoudi C, Gogos C, Samanidou V, Tziafas D, Palaghias G
Department of Basic Dental Sciences, School of Dentistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece.
Department of Endodontics, School of Dentistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece.
Dent Mater. 2016 Nov;32(11):e297-e305. doi: 10.1016/j.dental.2016.09.027. Epub 2016 Sep 23.
To evaluate the elution of HEMA, BPA, UDMA and BisGMA from a conventional resin cement (Multilink Automix, Ivoclar Vivadent) through human dentin, under constant positive pulpal pressure.
Ten human dentin disks (n=10) were adjusted in a new testing device and transparent glass slabs were luted with Multilink Automix resin cement, following manufacturer's instructions, under a steady pressure of 25N. The device was filled with Ringer's solution. At 5min, 20min, 1h, 2h, 21h, 3 days, 7 days, 10days and 21days time intervals, the whole eluate was retrieved from each one of the ten specimens and then, the specimens were refilled with fresh Ringer's solution. The eluates were analyzed by High Performance Liquid Chromatography (HPLC).
HEMA was detected in the eluate of all of the specimens, from 5min until 10 days. At four of the specimens, HEMA was also detected in the 21days eluate at very low concentrations. BPA, UDMA and BisGMA were not detected at any eluate. An unknown compound was also detected at 4.4min.
The concentrations of HEMA that enabled to diffuse from Multilink Automix cement in an aqueous solution, through a dentin barrier, did not reach toxic levels and BPA, UDMA and BisGMA were not detected at all.
评估在恒定的正牙髓压力下,常规树脂水门汀(Multilink Automix,义获嘉伟瓦登特公司)中的甲基丙烯酸羟乙酯(HEMA)、双酚A(BPA)、二甲基丙烯酸脲烷(UDMA)和双酚A双甲基丙烯酸缩水甘油酯(BisGMA)通过人牙本质的洗脱情况。
将十个人牙本质圆盘(n = 10)在一个新的测试装置中进行调整,按照制造商的说明,在25N的稳定压力下,用Multilink Automix树脂水门汀粘结透明玻璃片。该装置中充满林格氏液。在5分钟、20分钟、1小时、2小时、21小时、3天、7天、10天和21天的时间间隔时,从十个标本中的每一个中取出全部洗脱液,然后,用新鲜的林格氏液重新填充标本。通过高效液相色谱法(HPLC)分析洗脱液。
在所有标本的洗脱液中,从5分钟到10天均检测到HEMA。在四个标本中,在21天的洗脱液中也检测到极低浓度的HEMA。在任何洗脱液中均未检测到BPA、UDMA和BisGMA。在4.4分钟时还检测到一种未知化合物。
能够从Multilink Automix水门汀在水溶液中通过牙本质屏障扩散的HEMA浓度未达到有毒水平,并且根本未检测到BPA、UDMA和BisGMA。