Suppr超能文献

相似文献

1
Comparative Accuracy of 17 Point-of-Care Glucose Meters.
J Diabetes Sci Technol. 2017 May;11(3):558-566. doi: 10.1177/1932296816672237. Epub 2016 Oct 3.
3
Performance of blood glucose meters in compliance with current and future clinical ISO15197 accuracy criteria.
Curr Med Res Opin. 2014 Feb;30(2):185-90. doi: 10.1185/03007995.2013.858617. Epub 2013 Nov 6.
5
Accuracy of glucose meters in measuring low blood glucose levels.
J Med Assoc Thai. 2002 Nov;85 Suppl 4:S1104-10.
6
Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies.
Diabetes Technol Ther. 2016 Feb;18 Suppl 2(Suppl 2):S223-33. doi: 10.1089/dia.2015.0380.
10
The variability of results between point-of-care testing glucose meters and the central laboratory analyzer.
Arch Pathol Lab Med. 2006 Oct;130(10):1527-32. doi: 10.5858/2006-130-1527-TVORBP.

引用本文的文献

2
Non-Diabetic Hypoglycemia: Evaluation and Management in Adults.
J Clin Med. 2025 Jun 20;14(13):4393. doi: 10.3390/jcm14134393.
3
A Veteran Presenting With Symptomatic Postprandial Episodes.
Fed Pract. 2025 Feb;42(2):1-6. doi: 10.12788/fp.0541. Epub 2025 Feb 18.
4
Engineered Nanoparticles for μPAD Nucleic Acid Detection.
ACS Omega. 2025 May 13;10(20):20268-20276. doi: 10.1021/acsomega.4c11390. eCollection 2025 May 27.
5
Development of an isotope dilution gas chromatography - mass spectrometry candidate reference measurement procedure for glucose in human serum.
J Mass Spectrom Adv Clin Lab. 2025 Apr 17;36:63-72. doi: 10.1016/j.jmsacl.2025.04.005. eCollection 2025 Apr.
6
Managing discordance between HbA and glucose management indicator.
Diabet Med. 2025 Jun;42(6):e70023. doi: 10.1111/dme.70023. Epub 2025 Mar 23.
7
Clinical evaluation of a polarization-based optical noninvasive glucose sensing system.
Sci Rep. 2025 Mar 14;15(1):8877. doi: 10.1038/s41598-025-92515-6.
8
The Personal Glucose Meter as the Measurement Principle in Point-of-Care Applications.
Biosensors (Basel). 2025 Feb 19;15(2):121. doi: 10.3390/bios15020121.
10
Evaluation of the analytical and clinical accuracy of four blood glucose meters in pregnant women with hyperglycaemia.
Diabetes Obes Metab. 2025 Apr;27(4):2131-2137. doi: 10.1111/dom.16209. Epub 2025 Jan 24.

本文引用的文献

5
Evaluation of hematocrit interference with MyStar extra and seven competitive devices.
J Diabetes Sci Technol. 2015 Mar;9(2):262-7. doi: 10.1177/1932296814565790. Epub 2014 Dec 30.
7
Accuracy evaluation of blood glucose monitoring systems in children on overnight closed-loop control.
J Diabetes Sci Technol. 2014 Sep;8(5):969-73. doi: 10.1177/1932296814532238. Epub 2014 May 21.
8
Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations.
Clin Chim Acta. 2014 Jun 10;433:28-33. doi: 10.1016/j.cca.2014.02.023. Epub 2014 Mar 5.
10
Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.
Diabetes Technol Ther. 2014 Feb;16(2):113-22. doi: 10.1089/dia.2013.0208. Epub 2013 Nov 8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验