Suppr超能文献

四种树脂粘结水门汀粘结的氧化锆全冠微渗漏与绝对边缘差异的相关性:一项体外研究

Correlation between Microleakage and Absolute Marginal Discrepancy in Zirconia Crowns Cemented with Four Resin Luting Cements: An In Vitro Study.

作者信息

Cristian Abad-Coronel, Jeanette Li, Francisco Martínez-Rus, Guillermo Pradíes

机构信息

Department of Buccofacial Prostheses (Stomatology I), Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain.

出版信息

Int J Dent. 2016;2016:8084505. doi: 10.1155/2016/8084505. Epub 2016 Sep 18.

Abstract

. To evaluate microleakage and absolute marginal discrepancy (AMD) and to assess correlation between AMD and microleakage with four resin luting cements. . 20 extracted human third molars were prepared for full-coverage crowns. 20 zirconia copings were made (LAVA, 3M ESPE) and cemented. Specimens were randomly allocated for each used type of cement into 4 groups, RelyX® (Rx), Multilink® (Mk), PANAVIA 2.1® (P), and Maxcem® (Mx) and immersed in 10% safranin for 72 hours. 20x magnification lenses were used to observe microleakage areas (m) and images software was used to measure AMD areas (m). Discrepancy and microleakage between the cements were compared with one-way ANOVA test with confidence interval of 95%. . Rx Group showed microleakage has lowest value and AMD has highest value. P Group showed microleakage has the highest value and Mk Group presented AMD has lowest value. There were no significative differences between the cements. There were no linear correlations between microleakage and AMD; however a complex regression statistical model obtained allowed formulating an association between both variables (microleakage = AMD). . No significative differences were found among 4 types of cements. No linear correlations between AMD and microleakage were found. . AMD is not easily related to microleakage. Characteristics of cements are fundamental to decreasing of microleakage values.

摘要

评估四种树脂粘结水门汀的微渗漏和绝对边缘差异(AMD),并评估AMD与微渗漏之间的相关性。制备20颗拔除的人类第三磨牙以制作全冠。制作20个氧化锆基底冠(LAVA,3M ESPE)并进行粘结。将样本随机分为4组,每组使用一种类型的水门汀,即RelyX®(Rx)、Multilink®(Mk)、PANAVIA 2.1®(P)和Maxcem®(Mx),并浸泡在10%的番红溶液中72小时。使用20倍放大镜头观察微渗漏区域(m),并使用图像软件测量AMD区域(m)。采用95%置信区间的单因素方差分析对水门汀之间的差异和微渗漏进行比较。Rx组微渗漏值最低,AMD值最高。P组微渗漏值最高,Mk组AMD值最低。水门汀之间无显著差异。微渗漏与AMD之间无线性相关性;然而,所获得的复杂回归统计模型允许建立两个变量之间的关联(微渗漏 = AMD)。4种水门汀之间未发现显著差异。未发现AMD与微渗漏之间存在线性相关性。AMD不易与微渗漏相关。水门汀的特性对于降低微渗漏值至关重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2dcd/5046027/afcf8126dc18/IJD2016-8084505.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验