双焦点人工晶状体混合植入与三焦点人工晶状体双侧植入的比较

Comparison Between Mix-and-Match Implantation of Bifocal Intraocular Lenses and Bilateral Implantation of Trifocal Intraocular Lenses.

作者信息

Bilbao-Calabuig Rafael, González-López Felix, Amparo Ferrer, Alvarez Gemma, Patel Sunni R, Llovet-Osuna Fernando

出版信息

J Refract Surg. 2016 Oct 1;32(10):659-663. doi: 10.3928/1081597X-20160630-01.

Abstract

PURPOSE

To investigate the visual outcomes between mix-and-match bifocal intraocular lenses (IOLs) (ReSTOR +2.50 and +3.00 diopters [D]; Alcon Laboratories, Inc., Fort Worth, TX) versus bilateral implantation of a trifocal IOL (FineVision; PhysIOL, Liège, Belgium).

METHODS

Twenty-three patients (average age: 56.3 ± 6.9 years; range: 45 to 71 years) referred for lens phacoemulsification and IOL implantation were included in this study. Patients were randomly assigned to two groups. The FineVision group was bilaterally implanted with the FineVision trifocal IOL and the ReSTOR group was implanted with mix-and-match bifocal ReSTOR +2.50 and +3.00 D IOLs. A 3-month postoperative check was performed, and manifest refraction and logMAR uncorrected (UDVA) and corrected (CDVA) distance and near visual acuities were recorded. Monocular and binocular defocus curve testing was performed under photopic (85 cd/m) conditions in 0.50-D defocus steps. Contrast sensitivity was measured monocularly and binocularly under mesopic conditions at spatial frequencies of 3, 6, 12, and 18 cycles per degree using the CSV-1000 contrast test (VectorVision, Greenville, OH).

RESULTS

There were no reported differences in monocular distance visual acuity or refractive outcomes between groups (P > .05). Furthermore, there were no significant differences in contrast sensitivity between the three IOLs (P > .05). The FineVision group achieved better monocular and binocular near and intermediate visual acuities under defocus curve testing than the ReSTOR group (P < .05).

CONCLUSIONS

Binocular implantation of the FineVision trifocal IOL provided a better range of visual acuities at near and intermediate distances than mix-and-match bifocal IOL implantation. [J Refract Surg. 2016;32(10):659-663.].

摘要

目的

比较混合搭配双焦点人工晶状体(IOL)(ReSTOR +2.50和+3.00屈光度[D];爱尔康实验室公司,沃思堡,德克萨斯州)与双眼植入三焦点IOL(FineVision;PhysIOL,列日,比利时)的视觉效果。

方法

本研究纳入了23例因晶状体超声乳化和IOL植入而转诊的患者(平均年龄:56.3±6.9岁;范围:45至71岁)。患者被随机分为两组。FineVision组双眼植入FineVision三焦点IOL,ReSTOR组植入混合搭配的双焦点ReSTOR +2.50和+3.00 D IOL。术后3个月进行检查,记录明显验光以及未矫正(UDVA)和矫正(CDVA)的远视力和近视力。在明视(85 cd/m)条件下,以0.50 D的散焦步长进行单眼和双眼散焦曲线测试。使用CSV - 1000对比测试(VectorVision,格林维尔,俄亥俄州)在中视条件下,于每度3、6、12和18周波的空间频率下测量单眼和双眼对比敏感度。

结果

两组之间单眼远视力或屈光结果无报告差异(P>.05)。此外,三种IOL之间的对比敏感度无显著差异(P>.05)。在散焦曲线测试中,FineVision组比ReSTOR组获得了更好的单眼和双眼近视力和中视力(P<.05)。

结论

与混合搭配双焦点IOL植入相比,双眼植入FineVision三焦点IOL在近距和中距提供了更好的视力范围。[《屈光手术杂志》。2016;32(10):659 - 663。]