Suppr超能文献

在评估有毒气体吸入后的受试者时,振荡法可补充肺量测定法。

Oscillometry complements spirometry in evaluation of subjects following toxic inhalation.

作者信息

Berger Kenneth I, Turetz Meredith, Liu Mengling, Shao Yongzhao, Kazeros Angeliki, Parsia Sam, Caplan-Shaw Caralee, Friedman Stephen M, Maslow Carey B, Marmor Michael, Goldring Roberta M, Reibman Joan

机构信息

Dept of Medicine, Division of Pulmonary, Critical Care and Sleep Medicine, New York University School of Medicine, New York, NY, USA; André Cournand Pulmonary Physiology Laboratory, Bellevue Hospital, New York, NY, USA; These authors contributed equally to this manuscript.

Dept of Medicine, Division of Pulmonary, Critical Care and Sleep Medicine, New York University School of Medicine, New York, NY, USA; These authors contributed equally to this manuscript.

出版信息

ERJ Open Res. 2015 Dec 7;1(2). doi: 10.1183/23120541.00043-2015. eCollection 2015 Oct.

Abstract

The World Trade Center (WTC) destruction released dust and fumes into the environment. Although many community members developed respiratory symptoms, screening spirometry was usually normal. We hypothesised that forced oscillation testing would identify functional abnormalities undetected by spirometry and that symptom severity would relate to magnitude of abnormalities measured by oscillometry. A symptomatic cohort (n=848) from the Bellevue Hospital WTC Environmental Health Center was evaluated and compared to an asymptomatic cohort (n=475) from the New York City Department of Health WTC Health Registry. Spirometry and oscillometry were performed. Oscillometry measurements included resistance () and frequency dependence of resistance (). Spirometry was normal for the majority of subjects (73.2% symptomatic 87.6% asymptomatic, p<0.0001). In subjects with normal spirometry, and were higher in symptomatic asymptomatic subjects (median (interquartile range) 0.436 (0.206) 0.314 (0.129) kPa·L·s, p<0.001; 0.075 (0.085) 0.004 (0.042) kPa·L·s, p<0.0001). In symptomatic subjects, and increased with increasing severity and frequency of wheeze (p<0.05). Measurement of correlated with the presence and severity of symptoms even when spirometry was within normal limits. These findings are in accord with small airway abnormalities as a potential explanation of the respiratory symptoms.

摘要

世界贸易中心(WTC)被毁后向环境中释放了灰尘和烟雾。尽管许多社区成员出现了呼吸道症状,但筛查肺活量测定通常正常。我们推测强迫振荡测试能够识别出肺活量测定未检测到的功能异常,并且症状严重程度与振荡法测量的异常程度相关。对来自贝尔维尤医院WTC环境卫生中心的有症状队列(n = 848)进行了评估,并与来自纽约市卫生部门WTC健康登记处的无症状队列(n = 475)进行了比较。进行了肺活量测定和振荡测试。振荡测试测量包括阻力()和阻力的频率依赖性()。大多数受试者的肺活量测定正常(有症状者为73.2%,无症状者为87.6%,p<0.0001)。在肺活量测定正常的受试者中,有症状的受试者的和高于无症状的受试者(中位数(四分位间距)0.436(0.206)对0.314(0.129)kPa·L·s p<0.001;0.075(对0.085)对0.004(0.042)kPa·L·s,p<0.0001)。在有症状的受试者中,和随着喘息严重程度和频率的增加而增加(p<0.05)。即使肺活量测定在正常范围内,的测量也与症状的存在和严重程度相关。这些发现符合小气道异常是呼吸道症状潜在解释的观点。