Suppr超能文献

磁共振帕金森综合征指数:在一项针对进行性核上性麻痹患者的大型意大利多中心研究中,一种全自动算法与手动测量相比的诊断准确性。

Magnetic Resonance Parkinsonism Index: diagnostic accuracy of a fully automated algorithm in comparison with the manual measurement in a large Italian multicentre study in patients with progressive supranuclear palsy.

作者信息

Nigro Salvatore, Arabia Gennarina, Antonini Angelo, Weis Luca, Marcante Andrea, Tessitore Alessandro, Cirillo Mario, Tedeschi Gioacchino, Zanigni Stefano, Calandra-Buonaura Giovanna, Tonon Caterina, Pezzoli Gianni, Cilia Roberto, Zappia Mario, Nicoletti Alessandra, Cicero Calogero Edoardo, Tinazzi Michele, Tocco Pierluigi, Cardobi Nicolò, Quattrone Aldo

机构信息

Institute of Bioimaging and Molecular Physiology, National Research Council, 88100, Catanzaro, Italy.

Institute of Neurology, Department of Medical and Surgical Sciences, University 'Magna Graecia', 88100, Catanzaro, Italy.

出版信息

Eur Radiol. 2017 Jun;27(6):2665-2675. doi: 10.1007/s00330-016-4622-x. Epub 2016 Oct 19.

Abstract

OBJECTIVES

To investigate the reliability of a new in-house automatic algorithm for calculating the Magnetic Resonance Parkinsonism Index (MRPI), in a large multicentre study population of patients affected by progressive supranuclear palsy (PSP) or Parkinson's disease (PD), and healthy controls (HC), and to compare the diagnostic accuracy of the automatic and manual MRPI values.

METHODS

The study included 88 PSP patients, 234 PD patients and 117 controls. MRI was performed using both 3T and 1.5T scanners. Automatic and manual MRPI values were evaluated, and accuracy of both methods in distinguishing PSP from PD and controls was calculated.

RESULTS

No statistical differences were found between automated and manual MRPI values in all groups. The automatic MRPI values differentiated PSP from PD with an accuracy of 95 % (manual MRPI accuracy 96 %) and 97 % (manual MRPI accuracy 100 %) for 1.5T and 3T scanners, respectively.

CONCLUSION

Our study showed that the new in-house automated method for MRPI calculation was highly accurate in distinguishing PSP from PD. Our automatic approach allows a widespread use of MRPI in clinical practice and in longitudinal research studies.

KEY POINTS

• A new automatic method for calculating the MRPI is presented. • Automatic MRPI values are in good agreement with manual values. • Automatic MRPI can distinguish patients with PSP from patients with PD. • The automatic method overcomes MRPI application limitations in routine practice. • The automatic method may allow a more widespread use of MRPI.

摘要

目的

在一个由进行性核上性麻痹(PSP)或帕金森病(PD)患者以及健康对照(HC)组成的大型多中心研究人群中,研究一种新的内部自动算法计算磁共振帕金森综合征指数(MRPI)的可靠性,并比较自动和手动MRPI值的诊断准确性。

方法

该研究纳入了88例PSP患者、234例PD患者和117例对照。使用3T和1.5T扫描仪进行MRI检查。评估自动和手动MRPI值,并计算两种方法区分PSP与PD及对照的准确性。

结果

所有组中自动和手动MRPI值之间均未发现统计学差异。对于1.5T和3T扫描仪,自动MRPI值区分PSP与PD的准确性分别为95%(手动MRPI准确性为96%)和97%(手动MRPI准确性为100%)。

结论

我们的研究表明,新的内部自动计算MRPI的方法在区分PSP与PD方面具有高度准确性。我们的自动方法允许在临床实践和纵向研究中广泛使用MRPI。

关键点

• 提出了一种计算MRPI的新自动方法。• 自动MRPI值与手动值高度一致。• 自动MRPI可区分PSP患者与PD患者。• 自动方法克服了MRPI在常规实践中的应用限制。• 自动方法可能允许更广泛地使用MRPI。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验