Suppr超能文献

使用超声和光学相干断层扫描对从新鲜捐献的全眼球制备的供体内皮角膜移植透镜进行测量。

Measurements of donor endothelial keratoplasty lenticules prepared from fresh donated whole eyes by using ultrasound and optical coherence tomography.

作者信息

Kanavi Mozhgan Rezaei, Nemati Farzan, Chamani Tahereh, Kheiri Bahar, Javadi Mohammad Ali

机构信息

Ocular Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, No 23, Paidarfard-9th Boostan St., Pasdaran Ave, Tehran, 1666663111, Iran.

Central Eye Bank of Iran, Tehran, Iran.

出版信息

Cell Tissue Bank. 2017 Mar;18(1):99-104. doi: 10.1007/s10561-016-9599-9. Epub 2016 Nov 12.

Abstract

This study was conducted to analyze the profile and thickness of endothelial keratoplasty lenticules prepared from fresh donated whole eyes with Visante optical coherence tomography (V-OCT) compared to measurements obtained from ultrasound pachymetry (USP) at the Central Eye Bank of Iran. Microkeratome-assisted precut corneas were prepared for Descemet stripping automated endothelial keratoplasty by using standard eye bank protocol. Central posterior lenticule thickness (CPLT) on fresh whole eye, before excising corneoscleral disc and transferring to Optisol-GS, was measured by USP. V-OCT was used to measure central, paracentral, and midperipheral thicknesses of lenticules after transferring the tissue to Optisol-GS. Chi Square and Bonferroni tests were respectively used to uncover the differences between the USP and V-OCT measurements and also the thickness profile of lenticules. Postoperative reports for the entire transplanted lenticules were recorded. Accordingly, on evaluation of 312 enrolled precut corneas, CPLT measurements by V-OCT versus USP were statistically different (mean: 136 µm vs 165 µm, respectively; P = 0.008). Thickness profile of the posterior lenticules revealed increased thickness from the central to the peripheral parts of the cornea (mean increase of 16 µm at the pericentral and 64.2 µm at the peripheral locations, respectively); however, the increase in the thickness was relatively symmetrical. Postoperative reports of transplanted lenticules were unremarkable, since there were no posterior flap detachments. In essence, V-OCT measurements of microkeratome-assisted precut lenticules prepared from fresh donated whole eyes averaged 29 μm thinner than USP measurements and revealed a significant but symmetric increase of thickness towards the peripheral parts of the corneas. However, the variation in the thickness profile did not affect the attachment or the clarity of transplanted precut lenticlues.

摘要

本研究旨在通过Visante光学相干断层扫描(V-OCT)分析从伊朗中央眼库新鲜捐赠的全眼球制备的内皮角膜移植透镜的形态和厚度,并与超声测厚法(USP)获得的测量结果进行比较。按照标准眼库方案,使用微型角膜刀辅助制备预切割角膜,用于Descemet膜剥离自动内皮角膜移植术。在切除角巩膜瓣并转移至Optisol-GS之前,用USP测量新鲜全眼球上的中央后透镜厚度(CPLT)。将组织转移至Optisol-GS后,用V-OCT测量透镜的中央、旁中央和中周边厚度。分别使用卡方检验和Bonferroni检验来揭示USP和V-OCT测量结果之间的差异以及透镜的厚度形态。记录整个移植透镜的术后报告。因此,在评估312个纳入的预切割角膜时,V-OCT与USP测量的CPLT在统计学上存在差异(平均值分别为136μm和165μm;P = 0.008)。后透镜的厚度形态显示,从角膜中央到周边部分厚度增加(周边中央平均增加16μm,周边位置平均增加64.2μm);然而,厚度增加相对对称。移植透镜的术后报告无异常,因为没有后瓣脱离。从本质上讲,从新鲜捐赠的全眼球制备的微型角膜刀辅助预切割透镜的V-OCT测量结果平均比USP测量结果薄29μm,并且显示出向角膜周边部分厚度显著但对称增加。然而,厚度形态的变化并未影响移植预切割透镜的附着或清晰度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验