Yang Hyeri, Kim Da-Eun, Jang Won-Hee, An Susun, Cho Sun-A, Jung Mi-Sook, Lee Ji Eun, Yeo Kyung-Wook, Koh Sang Bum, Jeong Tae-Cheon, Kang Mi-Jeong, Chun Young-Jin, Lee Su-Hyon, Lim Kyung-Min, Bae SeungJin
College of Pharmacy, Ewha Womans University, Seoul 03760, Republic of Korea.
AmorePacific Corp. R&D Center, Yongin 17074, Republic of Korea.
Toxicol In Vitro. 2017 Mar;39:58-67. doi: 10.1016/j.tiv.2016.11.010. Epub 2016 Nov 19.
Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCE™. The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within-lab(WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean±SD or ±1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85-95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r>0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (>0.78), nevertheless weaker than the reproducibility of the viability. The EIT with MCTT HCE™ exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials.
在此,我们报告了一项使用重建人角膜样上皮MCTT HCE™进行体外眼刺激试验(EIT)的预验证试验结果。根据126种物质的受试者工作特征(ROC)曲线,预测模型中确定刺激的最佳截断值设定为35%。3个参与实验室对20种参考物质进行了实验室内(WL)和实验室间(BL)的重现性测试。用平均值±标准差或重复孔之间的±1/2差值描述的活力数据以及散点图,证明了WL/BL的一致性。WL/BL与二元判定(非刺激性或刺激性)的一致性估计分别为85 - 95%和95%。活力数据的WL/BL重现性还得到了强相关性(ICC,r>0.9)的进一步支持。二元判定的WL/BL一致性也通过Fleiss' Kappa统计进行了检验,结果显示一致性水平较高(>0.78),但仍弱于活力的重现性。对于126种参考物质,使用MCTT HCE™的EIT表现出82.2%(60/73)的敏感性、81.1%(43/53)的特异性和81.8%(103/126)的准确性(对于液体,敏感性为100%(47/47),特异性为70.6%(24/34),准确性为87.7%(71/81);对于固体,敏感性为50%(13/26),特异性为100%(19/19),准确性为71.1%(32/45)),这表明准确性令人满意,但敏感性需要改进,未来的全面验证试验中将通过纠正固体物质敏感性较差的问题来解决这一问题。