Abstract

The aim of our study was to estimate the intra- and inter-reader reproducibility of blood flow measurements in the ascending aorta and main pulmonary artery using cardiac magnetic resonance (CMR) and a semi-automated segmentation method. The ethics committee approved this retrospective study. A total of 50 consecutive patients (35 males and 15 females; mean age±standard deviation 27±13 years) affected by congenital heart disease were reviewed. They underwent CMR for flow analysis of the ascending aorta and main pulmonary artery (1.5 T, through-plane phase-contrast sequences). Two independent readers (R1, trained radiology resident; R2, lower-trained technician student) obtained segmented images twice (>10-day interval), using a semi-automated method of segmentation. Peak velocity, forward and backward flows were obtained. Bland-Altman analysis was used and reproducibility was reported as complement to 100% of the ratio between the coefficient of repeatability and the mean. R1 intra-reader reproducibility for the aorta was 99% (peak velocity), 95% (forward flow) and 49% (backward flow); for the pulmonary artery, 99%, 91% and 90%, respectively. R2 intra-reader reproducibility was 92%, 91% and 38%; 98%, 86% and 87%, respectively. Inter-reader reproducibility for the aorta was 91%, 85% and 20%; for the pulmonary artery 96%, 75%, and 82%, respectively. Our results showed a good to excellent reproducibility of blood flow measurements of CMR together with a semiautomated method of segmentation, for all variables except the backward flow of the ascending aorta, with a limited impact of operator's training.

摘要

我们的研究目的是评估使用心脏磁共振(CMR)和半自动分割方法测量升主动脉和主肺动脉血流的内-间读者可重复性。伦理委员会批准了这项回顾性研究。共回顾了 50 例连续先天性心脏病患者(男 35 例,女 15 例;平均年龄±标准差 27±13 岁)。他们接受了 CMR 检查,以分析升主动脉和主肺动脉的血流(1.5 T,平面相位对比序列)。两位独立的读者(R1,接受过放射科培训的住院医师;R2,接受过较少培训的技师学生)使用半自动分割方法两次获得分割图像(间隔>10 天)。获得峰值速度、前向和后向血流。采用 Bland-Altman 分析,将重复性报告为重复性系数与平均值之比的补充,报告为 100%。R1 读者对升主动脉的内-间重复性为 99%(峰值速度)、95%(前向血流)和 49%(后向血流);对肺动脉分别为 99%、91%和 90%。R2 读者的内-间重复性为 92%、91%和 38%;98%、86%和 87%。升主动脉的间-间重复性为 91%、85%和 20%;肺动脉分别为 96%、75%和 82%。我们的结果表明,使用 CMR 结合半自动分割方法,除升主动脉的后向血流外,所有变量的血流测量均具有良好至极好的可重复性,而操作者的培训影响有限。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验