Suppr超能文献

A Real-Time Kinect Signature-Based Patient Home Monitoring System.

作者信息

Blumrosen Gaddi, Miron Yael, Intrator Nathan, Plotnik Meir

机构信息

Blavatnik School of Computer Science, Tel Aviv University, Tel Aviv 69978, Israel.

Center of Advanced Technologies in Rehabilitation, Sheba Medical Center, Ramat Gan 52621, Israel.

出版信息

Sensors (Basel). 2016 Nov 23;16(11):1965. doi: 10.3390/s16111965.

Abstract

Assessment of body kinematics during performance of daily life activities at home plays a significant role in medical condition monitoring of elderly people and patients with neurological disorders. The affordable and non-wearable Microsoft Kinect ("Kinect") system has been recently used to estimate human subject kinematic features. However, the Kinect suffers from a limited range and angular coverage, distortion in skeleton joints' estimations, and erroneous multiplexing of different subjects' estimations to one. This study addresses these limitations by incorporating a set of features that create a unique "Kinect Signature". The Kinect Signature enables identification of different subjects in the scene, automatically assign the kinematics feature estimations only to the subject of interest, and provide information about the quality of the Kinect-based estimations. The methods were verified by a set of experiments, which utilize real-time scenarios commonly used to assess motor functions in elderly subjects and in subjects with neurological disorders. The experiment results indicate that the skeleton based Kinect Signature features can be used to identify different subjects in high accuracy. We demonstrate how these capabilities can be used to assign the Kinect estimations to the Subject of Interest, and exclude low quality tracking features. The results of this work can help in establishing reliable kinematic features, which can assist in future to obtain objective scores for medical analysis of patient condition at home while not restricted to perform daily life activities.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fd9f/5134624/4c8e7241ebe4/sensors-16-01965-g001.jpg

相似文献

1
A Real-Time Kinect Signature-Based Patient Home Monitoring System.
Sensors (Basel). 2016 Nov 23;16(11):1965. doi: 10.3390/s16111965.
3
Validity of the Kinect for Gait Assessment: A Focused Review.
Sensors (Basel). 2016 Feb 4;16(2):194. doi: 10.3390/s16020194.
4
5
Kinematic Validation of a Multi-Kinect v2 Instrumented 10-Meter Walkway for Quantitative Gait Assessments.
PLoS One. 2015 Oct 13;10(10):e0139913. doi: 10.1371/journal.pone.0139913. eCollection 2015.
6
Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking.
Gait Posture. 2015 Jul;42(2):145-51. doi: 10.1016/j.gaitpost.2015.05.002. Epub 2015 May 14.
7
Effects of camera viewing angles on tracking kinematic gait patterns using Azure Kinect, Kinect v2 and Orbbec Astra Pro v2.
Gait Posture. 2021 Jun;87:19-26. doi: 10.1016/j.gaitpost.2021.04.005. Epub 2021 Apr 5.
8
Kinect v2 tracked Body Joint Smoothing for Kinematic Analysis in Musculoskeletal Disorders.
Annu Int Conf IEEE Eng Med Biol Soc. 2020 Jul;2020:5769-5772. doi: 10.1109/EMBC44109.2020.9175492.
10
Validity of time series kinematical data as measured by a markerless motion capture system on a flatland for gait assessment.
J Biomech. 2018 Apr 11;71:281-285. doi: 10.1016/j.jbiomech.2018.01.035. Epub 2018 Feb 8.

引用本文的文献

2
Cognitive telerehabilitation: an expert consensus paper on current evidence and future perspective.
Front Neurol. 2024 Feb 15;15:1338873. doi: 10.3389/fneur.2024.1338873. eCollection 2024.
4
ST-DeepGait: A Spatiotemporal Deep Learning Model for Human Gait Recognition.
Sensors (Basel). 2022 Oct 21;22(20):8075. doi: 10.3390/s22208075.
6
Development and Validation of 2D-LiDAR-Based Gait Analysis Instrument and Algorithm.
Sensors (Basel). 2021 Jan 8;21(2):414. doi: 10.3390/s21020414.
8
Extraction and Research of Crop Feature Points Based on Computer Vision.
Sensors (Basel). 2019 Jun 4;19(11):2553. doi: 10.3390/s19112553.
10
A Telerehabilitation System for the Selection, Evaluation and Remote Management of Therapies.
Sensors (Basel). 2018 May 8;18(5):1459. doi: 10.3390/s18051459.

本文引用的文献

1
Privacy-Aware Relevant Data Access with Semantically Enriched Search Queries for Untrusted Cloud Storage Services.
PLoS One. 2016 Aug 29;11(8):e0161440. doi: 10.1371/journal.pone.0161440. eCollection 2016.
2
Learning dictionaries of sparse codes of 3D movements of body joints for real-time human activity understanding.
PLoS One. 2014 Dec 4;9(12):e114147. doi: 10.1371/journal.pone.0114147. eCollection 2014.
4
A motor learning-based intervention to ameliorate freezing of gait in subjects with Parkinson's disease.
J Neurol. 2014 Jul;261(7):1329-39. doi: 10.1007/s00415-014-7347-2. Epub 2014 Apr 23.
7
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease.
Gait Posture. 2014 Apr;39(4):1062-8. doi: 10.1016/j.gaitpost.2014.01.008. Epub 2014 Jan 22.
8
Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry.
Gait Posture. 2014;39(1):593-8. doi: 10.1016/j.gaitpost.2013.09.018. Epub 2013 Oct 5.
9
Efficient human pose estimation from single depth images.
IEEE Trans Pattern Anal Mach Intell. 2013 Dec;35(12):2821-40. doi: 10.1109/TPAMI.2012.241.
10
Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables.
J Biomech. 2013 Oct 18;46(15):2722-5. doi: 10.1016/j.jbiomech.2013.08.011. Epub 2013 Aug 26.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验