Suppr超能文献

中年女性肩部测量的评分者间信度

Inter-rater reliability of shoulder measurements in middle-aged women.

作者信息

De Groef A, Van Kampen M, Vervloesem N, Clabau E, Christiaens M-R, Neven P, Geraerts I, Struyf F, Devoogdt N

机构信息

Department of Rehabilitation Sciences, KU Leuven - University of Leuven, Leuven, Belgium; Department of Physical Medicine and Rehabilitation, University Hospitals Leuven, Leuven, Belgium.

Department of Rehabilitation Sciences, KU Leuven - University of Leuven, Leuven, Belgium; Department of Physical Medicine and Rehabilitation, University Hospitals Leuven, Leuven, Belgium.

出版信息

Physiotherapy. 2017 Jun;103(2):222-230. doi: 10.1016/j.physio.2016.07.002. Epub 2016 Jul 20.

Abstract

OBJECTIVES

To investigate inter-rater reliability of a set of shoulder measurements including inclinometry [shoulder range of motion (ROM)], acromion-table distance and pectoralis minor muscle length (static scapular positioning), upward rotation with two inclinometers (scapular kinematics) and pain pressure thresholds (muscle tenderness) in middle-aged women.

DESIGN

Observational study.

PARTICIPANTS

Thirty symptom-free middle-aged women (first cohort) were measured by two raters. All measurements with an intraclass correlation coefficient (ICC) below 0.75 were retested after an additional training period in a second cohort of 30 symptom-free middle-aged women.

MAIN OUTCOME MEASURES

Inter-rater reliability of all variables was measured with the ICC (95% confidence interval) and standard error of measurement (SEM).

RESULTS

Acromion-table distance (ICC=0.91, SEM 0.22 to 0.28% of body length), pectoralis minor muscle length (ICC=0.91, SEM 0.16% of body length), pain pressure thresholds (ICC=0.78 to 0.85, SEM 0.39 to 0.70kg) and abduction ROM (ICC=0.77, SEM 5°) showed good to excellent inter-rater reliability in the first cohort. After an additional training period, forward flexion ROM showed good inter-rater reliability (ICC=0.83, SEM 5°), scapular upward rotation in resting position showed moderate reliability (ICC=0.52, SEM 2°), and other scaption angles showed weak reliability (ICC=0.26 to 0.43, SEM 3 to 8°).

CONCLUSIONS

In a battery of clinical tools to evaluate factors contributing to shoulder pain, static scapular positioning and pressure pain thresholds were found to have good to excellent inter-rater reliability in middle-aged women. Additional training is recommended for measurements with a gravity inclinometer.

摘要

目的

研究一组肩部测量指标在中年女性中的评分者间信度,这些指标包括测角法[肩部活动范围(ROM)]、肩峰-桌面距离和胸小肌长度(静态肩胛骨定位)、使用两个测角仪测量的向上旋转(肩胛骨运动学)以及疼痛压力阈值(肌肉压痛)。

设计

观察性研究。

参与者

30名无症状中年女性(第一组)由两名评分者进行测量。在另一组30名无症状中年女性接受额外训练期后,对所有组内相关系数(ICC)低于0.75的测量指标进行重新测试。

主要观察指标

使用ICC(95%置信区间)和测量标准误差(SEM)来测量所有变量的评分者间信度。

结果

在第一组中,肩峰-桌面距离(ICC = 0.91,SEM为身长的0.22%至0.28%)、胸小肌长度(ICC = 0.91,SEM为身长的0.16%)、疼痛压力阈值(ICC = 0.78至0.85,SEM为0.39至0.70kg)和外展ROM(ICC = 0.77,SEM为5°)显示出良好至优秀的评分者间信度。在额外训练期后,前屈ROM显示出良好的评分者间信度(ICC = 0.83,SEM为5°),静息位肩胛骨向上旋转显示出中等信度(ICC = 0.52,SEM为2°),其他斜方角显示出较弱的信度(ICC = 0.26至0.43,SEM为3至8°)。

结论

在一系列用于评估导致肩部疼痛因素的临床工具中,发现静态肩胛骨定位和压力疼痛阈值在中年女性中具有良好至优秀的评分者间信度。对于使用重力测角仪进行的测量,建议进行额外培训。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验