Sci Justice. 2016 Dec;56(6):468-474. doi: 10.1016/j.scijus.2016.06.008. Epub 2016 Jun 23.
Many forensic STR kits are currently available in the market. The AmpFLSTR® Identifiler® Plus kit, which targets 15 STRs, is commonly used worldwide. The Thai forensic DNA community is built around it in terms of instrument, databases, and interpretation. QIAGEN's IDplex Plus kit targets the same loci, but the PCR cycling time is shorter by about 90min. A direct comparison that assesses forensic parameters and applicability to casework between the two kits has never been carried out. In this study, we performed a direct comparison between the two kits using serial dilutions of two control DNA samples and 60 randomly selected casework samples, including samples taken from improvised explosive devices and terrorist raids. We statistically compared the performance of the two kits in terms of peak height, number of allele detected (allelic drop-out), intra-locus balance, inter-locus balance, inhibitor tolerance, stutter ratio, concordance, and allelic drop-in. The results demonstrate that both kits are statistically similar in performance. IDplex Plus gave higher peak heights in sensitivity test and tolerated inhibitors better, but had slightly worse inter-locus balances and stutter ratios. However, these differences were not practically significant, as seen by the resulting profiles of the casework samples (p=0.601). The performance on low-template samples also was not different. In conclusion, laboratories looking to replace the aging Identifiler® Plus might consider the IDplex Plus as a faster, more robust alternative that fits right into their existing structure without further investment in instrument and DNA database. Having more kits available worldwide by different companies could help bring the technology to different forensic laboratories and the justice system as a whole.
目前市场上有许多法医STR试剂盒。AmpFLSTR® Identifiler® Plus试剂盒针对15个STR基因座,在全球范围内广泛使用。泰国法医DNA领域在仪器、数据库和解读方面都围绕着它建立起来。QIAGEN的IDplex Plus试剂盒针对相同的基因座,但PCR循环时间缩短了约90分钟。从未对这两种试剂盒之间的法医参数和在实际案件工作中的适用性进行过直接比较。在本研究中,我们使用两个对照DNA样本的系列稀释液和60个随机选择的实际案件样本,包括从简易爆炸装置和恐怖袭击中获取的样本,对这两种试剂盒进行了直接比较。我们从峰高、检测到的等位基因数量(等位基因缺失)、基因座内平衡、基因座间平衡、抑制剂耐受性、拖带率、一致性和等位基因插入等方面对两种试剂盒的性能进行了统计学比较。结果表明,两种试剂盒在性能上在统计学上相似。IDplex Plus在灵敏度测试中峰高更高,对抑制剂的耐受性更好,但基因座间平衡和拖带率略差。然而,从实际案件样本的结果来看,这些差异并不具有实际意义(p = 0.601)。在低模板样本上的性能也没有差异。总之,希望更换老化的Identifiler® Plus试剂盒的实验室可以考虑将IDplex Plus作为一种更快、更强大的替代品,它可以直接融入其现有结构,而无需对仪器和DNA数据库进行进一步投资。全球有不同公司提供更多试剂盒,有助于将该技术推广到不同的法医实验室和整个司法系统。