Suppr超能文献

用于评估大鼠肾功能且无需收集尿液的血浆清除率计算简易公式。

Simple equation for calculation of plasma clearance for evaluation of renal function without urine collection in rats.

作者信息

Liu Xiang, Peng Dejun, Tian Hao, Lu Chengyu

机构信息

Department of Pharmacology, Faculty of Pharmacy, Guangdong Medical University, Dongguan, Guangdong, China.

出版信息

Nephrology (Carlton). 2017 Jan;22(1):89-94. doi: 10.1111/nep.12826.

Abstract

To develop an equation for the evaluation of renal function in rats using three dilutions of plasma samples and to validate this method by comparison with a reference method. The investigation was conducted in Sprague-Dawley (SD) rats after delivery of three doses of iohexol, with blood samples collected before and after dosage using a quantitative blood collection method. Plasma iohexol concentrations were detected by high performance liquid chromatography (HPLC). The extraction recovery of iohexol from plasma was >97.30% and the calibration curve was linear (r  = 0.9997) over iohexol concentrations ranging from 10 to 1000 µg/mL. The method had an RE of <9.310 and intra- and inter-day RSD of <5.137% and <3.693%, respectively. The plasma clearance values obtained from the equation correlated closely (r = 0.763) with those obtained using the reference method. The relatively correlation in the results obtained using the method under investigation and the reference method indicate that this new equation can be used for preliminary assessment of renal function in rats.

摘要

建立一个使用血浆样本的三种稀释度来评估大鼠肾功能的方程,并通过与参考方法比较来验证该方法。在给Sprague-Dawley(SD)大鼠注射三剂碘海醇后进行研究,使用定量采血方法在给药前后采集血样。通过高效液相色谱法(HPLC)检测血浆碘海醇浓度。碘海醇从血浆中的提取回收率>97.30%,校准曲线在10至1000μg/mL的碘海醇浓度范围内呈线性(r = 0.9997)。该方法的相对误差<9.310,日内和日间相对标准偏差分别<5.137%和<3.693%。从该方程获得的血浆清除率值与使用参考方法获得的值密切相关(r = 0.763)。所研究方法与参考方法所得结果的相对相关性表明,这个新方程可用于大鼠肾功能的初步评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验