一种用于检测尿液中可卡因代谢物苯甲酰芽子碱的灵敏检测方法,与使用传统临界值的方法相比,显示出更多的阳性结果和更长的半衰期。

A sensitive assay for urinary cocaine metabolite benzoylecgonine shows more positive results and longer half-lives than those using traditional cut-offs.

作者信息

Nickley Joyce, Pesce Amadeo J, Krock Kevin

机构信息

Precision Diagnostics LLC, Laboratory, 4215 Sorrento Valley Boulevard, San Diego, CA, 92121, USA.

出版信息

Drug Test Anal. 2017 Aug;9(8):1214-1216. doi: 10.1002/dta.2153. Epub 2017 Mar 3.

Abstract

Cocaine is a common drug of abuse. To detect its use, a screening detection concentration for the cocaine metabolite benzoylecgonine is commonly set at 150 ng/mL and its confirmatory cut-off is set at 100 ng/mL. Studies have suggested that these cut-offs may be set too high, allowing some patients with this substance abuse problem to be missed or improperly monitored. With the advent of liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology it is possible to reliably detect and quantify lower concentrations of its metabolite benzoylecgonine as part of a larger drug panel. One purpose of the study was to establish if there was a significant increase in detection of cocaine use with a ten-fold more sensitive cut-off. A very sensitive dilute and shoot assay for benzoylecgonine was developed with a lower limit of quantitation of 5 ng/mL. Validation of the 5 ng/mL cut-off was achieved by plotting all the positive cocaine observations as a frequency distribution on a logarithmic scale. The number of positive results with measurable concentrations below the typical industry 100 ng/mL cut-off level but above the high sensitivity 5 ng/mL cut-off level was observed to be 51.9% of the observed positives. The lower cut-off also allowed a re-evaluation of the window of detection after cessation of use. It was observed to be between 17 and 22 days. © 2016 Precision Diagnostics, LLC. Drug Testing and Analysis published by John Wiley & Sons, Ltd.

摘要

可卡因是一种常见的滥用药物。为了检测其使用情况,可卡因代谢物苯甲酰爱康宁的筛查检测浓度通常设定为150纳克/毫升,其确证临界值设定为100纳克/毫升。研究表明,这些临界值可能设定得过高,导致一些有药物滥用问题的患者被漏诊或监测不当。随着液相色谱-串联质谱(LC-MS/MS)技术的出现,作为更大药物检测组的一部分,能够可靠地检测和定量更低浓度的其代谢物苯甲酰爱康宁。该研究的一个目的是确定将临界值提高十倍以提高灵敏度后,可卡因使用情况的检测是否有显著增加。开发了一种对苯甲酰爱康宁非常灵敏的稀释进样分析法,定量下限为5纳克/毫升。通过将所有可卡因阳性观察结果以对数标度绘制成频率分布,实现了对5纳克/毫升临界值的验证。观察到,可测量浓度低于行业典型的100纳克/毫升临界值但高于高灵敏度5纳克/毫升临界值的阳性结果数量占观察到的阳性结果的51.9%。更低的临界值还使得能够重新评估停止使用后的检测窗口期。观察到该窗口期在17至22天之间。© 2016精准诊断有限责任公司。《药物检测与分析》,由约翰·威利父子有限公司出版

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cf9b/5573903/d3666d5cc001/DTA-9-1214-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验