Clinical Research Assistant Professor, Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, Seoul, Republic of Korea.
Graduate student, Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, Seoul, Republic of Korea.
J Prosthet Dent. 2017 Jul;118(1):18-25.e4. doi: 10.1016/j.prosdent.2016.10.004. Epub 2016 Dec 23.
Since 2007, the FDI World Dental Federation (FDI) criteria have been used for the clinical evaluation of dental restorations. However, the reliability of the FDI criteria has not been sufficiently addressed.
The purpose of this study was to assess and compare the interrater and intrarater reliability of the FDI criteria by evaluating posterior tooth-colored restorations photographically.
A total of 160 clinical photographs of posterior tooth-colored restorations were evaluated independently by 5 raters with 9 of the FDI criteria suitable for photographic evaluation. The raters recorded the score of each restoration by using 5 grades, and the score was dichotomized into the clinical evaluation scores. After 1 month, 2 of the raters reevaluated the same set of 160 photographs in random order. To estimate the interrater reliability among the 5 raters, the proportion of agreement was calculated, and the Fleiss multirater kappa statistic was used. For the intrarater reliability, the proportion of agreement was calculated, and the Cohen standard kappa statistic was used for each of the 2 raters.
The interrater proportion of agreement was 0.41 to 0.57, and the kappa value was 0.09 to 0.39. Overall, the intrarater reliability was higher than the interrater reliability, and rater 1 demonstrated higher intrarater reliability than rater 2. The proportion of agreement and kappa values increased when the 5 scores were dichotomized. The reliability was relatively lower for the esthetic properties compared with the functional or biological properties.
Within the limitations of this study, the FDI criteria presented slight to fair interrater reliability and fair to excellent intrarater reliability in the photographic evaluation of posterior tooth-colored restorations. The reliability was improved by simplifying the evaluation scores.
自 2007 年以来,国际牙科联盟(FDI)标准一直被用于牙科修复体的临床评估。然而,FDI 标准的可靠性尚未得到充分解决。
本研究旨在通过对后牙牙色修复体进行摄影评估,评估和比较 FDI 标准的评估者间和评估者内可靠性。
共有 160 张后牙牙色修复体的临床照片由 5 名评估者独立评估,其中 9 项 FDI 标准适用于摄影评估。评估者使用 5 个等级记录每个修复体的评分,并将评分分为临床评估评分。1 个月后,2 名评估者随机重新评估相同的 160 张照片集。为了评估 5 名评估者之间的评估者间可靠性,计算了一致性比例,并使用弗莱思多评估者κ统计量。对于评估者内可靠性,计算了一致性比例,并为每个评估者使用 Cohen 标准κ统计量。
评估者间的一致性比例为 0.41 至 0.57,κ 值为 0.09 至 0.39。总体而言,评估者内可靠性高于评估者间可靠性,评估者 1 的评估者内可靠性高于评估者 2。当将 5 个评分分为两组时,一致性比例和κ 值增加。与功能或生物学特性相比,美学特性的可靠性相对较低。
在本研究的限制范围内,FDI 标准在对后牙牙色修复体的摄影评估中表现出轻微至中等的评估者间可靠性和良好至优秀的评估者内可靠性。通过简化评估评分,可靠性得到了提高。