Suppr超能文献

计算机断层扫描衰减值在心包积液特征描述中的有效性。

Effectiveness of computed tomography attenuation values in characterization of pericardial effusion.

作者信息

Çetin Mehmet Serkan, Özcan Çetin Elif Hande, Özdemir Mustafa, Topaloğlu Serkan, Aras Dursun, Temizhan Ahmet, Aydoğdu Sinan

机构信息

Department of Cardiology, Türkiye Yüksek İhtisas Training and Research Hospital; Ankara-Turkey.

出版信息

Anatol J Cardiol. 2017 Apr;17(4):322-327. doi: 10.14744/AnatolJCardiol.2016.7353. Epub 2017 Jan 17.

Abstract

OBJECTIVE

The aim of this study was to evaluate the effectiveness of computed tomography (CT) attenuation values in the characterization of pericardial effusion.

METHODS

This study consisted of 96 patients with pericardial effusion who underwent pericardiocentesis. For further diagnostic evaluation of pericardial effusion, all the patients were assessed by thorax CT. CT attenuation values were measured from at least 5 different areas of pericardial fluid by specifying the largest region of interest. The average of these measurements was computed and considered as the CT attenuation value of the patient. The patients were classified into two groups: patients with transudative pericardial effusion and those with exudative pericardial effusion.

RESULTS

CT attenuation values were significantly higher in patients with exudative pericardial effusion than in those with transudative pericardial effusion [14.85±10.7 Hounsfield unit (HU) vs. 1.13±4.3 HU, p<0.001]. CT attenuation values had a close correlation with the pericardial fluid albumin (r=0.829), protein (r=0.752), and LDH (r=0.708) levels; WBC count (r=0.564); protein ratio (r=0.739); and LDH ratio (r=0.689) as well as the albumin gradient (r=-0.725). A cut-off value of 4.7 HU had 80% sensitivity and 87.7% specificity for the identification of exudative pericardial effusion. In addition, a cut-off value of 6.5 HU had 71.4% sensitivity and 72.3% specificity for the prediction of cardiac tamponade.

CONCLUSION

In patients with pericardial effusion, CT attenuation values seem to be correlated with the characterization parameters of the fluid and may distinguish exudative pericardial effusion from transudative pericardial effusion. This parameter was also found to be a predictor of cardiac tamponade. CT attenuation values can be a useful tool in the clinical evaluation of patients with pericardial effusion.

摘要

目的

本研究旨在评估计算机断层扫描(CT)衰减值在鉴别心包积液特征方面的有效性。

方法

本研究纳入了96例行心包穿刺术的心包积液患者。为了对心包积液进行进一步的诊断评估,所有患者均接受胸部CT检查。通过指定最大感兴趣区,从心包积液至少5个不同区域测量CT衰减值。计算这些测量值的平均值,并将其视为患者的CT衰减值。患者被分为两组:漏出性心包积液患者和渗出性心包积液患者。

结果

渗出性心包积液患者的CT衰减值显著高于漏出性心包积液患者[14.85±10.7亨氏单位(HU)对1.13±4.3 HU,p<0.001]。CT衰减值与心包积液白蛋白(r=0.829)、蛋白质(r=0.752)和乳酸脱氢酶(LDH)(r=0.708)水平;白细胞计数(r=0.564);蛋白比值(r=0.739);以及LDH比值(r=0.689)以及白蛋白梯度(r=-0.725)密切相关。4.7 HU的截断值对鉴别渗出性心包积液的敏感性为80%,特异性为87.7%。此外,6.5 HU的截断值对预测心脏压塞的敏感性为71.4%,特异性为72.3%。

结论

在心包积液患者中,CT衰减值似乎与积液的特征参数相关,并且可以区分渗出性心包积液和漏出性心包积液。该参数还被发现是心脏压塞的一个预测指标。CT衰减值可成为心包积液患者临床评估中的有用工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8fb2/5469113/ec502dc25b3a/AJC-17-322-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验