Suppr超能文献

冈上肌及其肌腱的剪切波弹性成像:重复性及初步研究结果。

Shear wave elastography of the supraspinatus muscle and tendon: Repeatability and preliminary findings.

作者信息

Baumer Timothy G, Davis Leah, Dischler Jack, Siegal Daniel S, van Holsbeeck Marnix, Moutzouros Vasilios, Bey Michael J

机构信息

Department of Orthopaedic Surgery, Bone and Joint Center, Henry Ford Health System, USA.

Department of Radiology, Henry Ford Health System, USA.

出版信息

J Biomech. 2017 Feb 28;53:201-204. doi: 10.1016/j.jbiomech.2017.01.008. Epub 2017 Jan 18.

Abstract

Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the extent to which active and passive conditions affect shear wave speed (SWS) repeatability. Probe positioning and human usage errors were assessed by acquiring SWE images from custom ultrasound phantoms. Intra- and inter-user repeatability were assessed by two users acquiring five trials of supraspinatus muscle and tendon SWE images from ten human subjects. To assess day-to-day repeatability, five of the subjects were tested a second time, approximately 24h later. Imaging of the phantoms indicated high inter-user repeatability, with intraclass correlation coefficient (ICC) values of 0.68-0.85, and RMS errors of no more than 4.1%. SWE imaging of the supraspinatus muscle and tendon had high repeatability, with intra- and inter-user ICC values of greater than 0.87 and 0.73, respectively. Day-to-day repeatability demonstrated ICC values greater than 0.33 for passive muscle, 0.48 for passive tendon, 0.65 for active muscle, and 0.94 for active tendon. This study indicates the technique has good to very good intra- and inter-user repeatability, and day-to-day repeatability is appreciably higher when SWE images are acquired under a low level of muscle activation. The findings from this study establish the feasibility and repeatability of SWE for acquiring data longitudinally in human subjects.

摘要

剪切波弹性成像(SWE)是一种很有前景的用于评估肌肉骨骼组织特性的工具,但很少有研究对其重复性和误差来源进行严格评估。本研究的目的是评估:(1)探头定位误差和使用者人为误差对测量准确性的影响程度;(2)使用者内、使用者间以及日常的重复性;(3)主动和被动条件对剪切波速度(SWS)重复性的影响程度。通过从定制超声体模获取SWE图像来评估探头定位和人为使用误差。由两名使用者从十名受试者获取五次冈上肌和肌腱SWE图像来评估使用者内和使用者间的重复性。为评估日常重复性,对其中五名受试者在大约24小时后进行第二次测试。体模成像显示使用者间具有较高的重复性,组内相关系数(ICC)值为0.68 - 0.85,均方根误差不超过4.1%。冈上肌和肌腱的SWE成像具有较高的重复性,使用者内和使用者间的ICC值分别大于0.87和0.73。日常重复性显示,被动肌肉的ICC值大于0.33,被动肌腱为0.48,主动肌肉为0.65,主动肌腱为0.94。本研究表明该技术具有良好至极优的使用者内和使用者间重复性,并且当在低水平肌肉激活状态下获取SWE图像时,日常重复性明显更高。本研究结果证实了SWE在人类受试者中纵向获取数据的可行性和重复性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验