Suppr超能文献

前列腺健康指数和4-激肽释放酶评分预测总体和高级别前列腺癌诊断准确性的系统评价与荟萃分析

A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Prostate Health Index and 4-Kallikrein Panel Score in Predicting Overall and High-grade Prostate Cancer.

作者信息

Russo Giorgio Ivan, Regis Federica, Castelli Tommaso, Favilla Vincenzo, Privitera Salvatore, Giardina Raimondo, Cimino Sebastiano, Morgia Giuseppe

机构信息

Department of Surgery, Urology Section, University of Catania, Catania, Italy.

Department of Surgery, Urology Section, University of Catania, Catania, Italy.

出版信息

Clin Genitourin Cancer. 2017 Aug;15(4):429-439.e1. doi: 10.1016/j.clgc.2016.12.022. Epub 2016 Dec 30.

Abstract

Markers for prostate cancer (PCa) have progressed over recent years. In particular, the prostate health index (PHI) and the 4-kallikrein (4K) panel have been demonstrated to improve the diagnosis of PCa. We aimed to review the diagnostic accuracy of PHI and the 4K panel for PCa detection. We performed a systematic literature search of PubMed, EMBASE, Cochrane, and Academic One File databases until July 2016. We included diagnostic accuracy studies that used PHI or 4K panel for the diagnosis of PCa or high-grade PCa. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Twenty-eight studies including 16,762 patients have been included for the analysis. The pooled data showed a sensitivity of 0.89 and 0.74 for PHI and 4K panel, respectively, for PCa detection and a pooled specificity of 0.34 and 0.60 for PHI and 4K panel, respectively. The derived area under the curve (AUC) from the hierarchical summary receiver operating characteristic (HSROC) showed an accuracy of 0.76 and 0.72 for PHI and 4K panel respectively. For high-grade PCa detection, the pooled sensitivity was 0.93 and 0.87 for PHI and 4K panel, respectively, whereas the pooled specificity was 0.34 and 0.61 for PHI and 4K panel, respectively. The derived AUC from the HSROC showed an accuracy of 0.82 and 0.81 for PHI and 4K panel, respectively. Both PHI and the 4K panel provided good diagnostic accuracy in detecting overall and high-grade PCa.

摘要

近年来,前列腺癌(PCa)的标志物取得了进展。特别是,前列腺健康指数(PHI)和4-激肽释放酶(4K)检测组合已被证明可改善PCa的诊断。我们旨在综述PHI和4K检测组合对PCa检测的诊断准确性。我们对PubMed、EMBASE、Cochrane和Academic One File数据库进行了系统的文献检索,直至2016年7月。我们纳入了使用PHI或4K检测组合诊断PCa或高级别PCa的诊断准确性研究。使用诊断准确性研究质量评估(QUADAS-2)工具评估方法学质量。纳入了28项研究,共16762例患者进行分析。汇总数据显示,PHI和4K检测组合检测PCa的敏感性分别为0.89和0.74,PHI和4K检测组合的汇总特异性分别为0.34和0.60。分层汇总接受者操作特征(HSROC)得出的曲线下面积(AUC)显示,PHI和4K检测组合的准确性分别为0.76和0.72。对于高级别PCa检测,PHI和4K检测组合的汇总敏感性分别为0.93和0.87,而PHI和4K检测组合的汇总特异性分别为0.34和0.61。HSROC得出的AUC显示,PHI和4K检测组合的准确性分别为0.82和0.81。PHI和4K检测组合在检测总体PCa和高级别PCa方面均具有良好的诊断准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验