OBJECTIVE

In this study, a wearable actigraphy recording device with low sampling rate (1 Hz) for power saving and data reduction and a high accuracy wake-sleep scoring method for the assessment of sleep were developed.

METHODS

The developed actigraphy recorder was successfully applied to overnight recordings of 81 subjects with simultaneous polysomnography (PSG) measurements. The total length of recording reached 639.8 h. A wake-sleep scoring method based on the concept of movement density evaluation and adaptive windowing was proposed. Data from subjects with good (N = 43) and poor (N = 16) sleep efficiency (SE) in the range of 52.7-97.42% were used for testing. The Bland-Altman technique was used to evaluate the concordance of various sleep measurements between the manual PSG scoring and the proposed actigraphy method.

RESULTS

For wake-sleep staging, the average accuracy, sensitivity, specificity, and kappa coefficient of the proposed system were 92.16%, 95.02%, 71.30%, and 0.64, respectively. For the assessment of SE, the accuracy of classifying the subject with good or poor SE reached 91.53%. The mean biases of SE, sleep onset time, wake after sleep onset, and total sleep time were -0.95%, 0.74 min, 2.84 min, and -4.3 min, respectively.

CONCLUSION

These experimental results demonstrate the robustness and reliability of our method using limited activity information to estimate wake-sleep stages during overnight recordings.

SIGNIFICANCE

The results suggest that the proposed wearable actigraphy system is practical for the in-home screening of objective sleep measurements and objective evaluation of sleep improvement after treatment.

摘要

目的

在本研究中,开发了一种用于节能和数据缩减的低采样率(1Hz)可穿戴活动记录仪以及一种用于睡眠评估的高精度睡眠-觉醒评分方法。

方法

所开发的活动记录仪成功应用于81名受试者的夜间记录,并同时进行多导睡眠图(PSG)测量。记录总时长达到639.8小时。提出了一种基于运动密度评估和自适应窗口概念的睡眠-觉醒评分方法。使用睡眠效率(SE)在52.7 - 97.42%范围内的睡眠良好(N = 43)和睡眠不佳(N = 16)受试者的数据进行测试。采用Bland - Altman技术评估手动PSG评分与所提出的活动记录法之间各种睡眠测量的一致性。

结果

对于睡眠-觉醒分期,所提出系统的平均准确率、灵敏度、特异性和kappa系数分别为92.16%、95.02%、71.30%和0.64。对于SE评估,将受试者分类为SE良好或不佳的准确率达到91.53%。SE、入睡时间、睡眠中觉醒时间和总睡眠时间的平均偏差分别为 - 0.95%、0.74分钟、2.84分钟和 - 4.3分钟。

结论

这些实验结果证明了我们使用有限活动信息在夜间记录期间估计睡眠-觉醒阶段的方法的稳健性和可靠性。

意义

结果表明,所提出 的可穿戴活动记录系统对于在家中客观睡眠测量的筛查以及治疗后睡眠改善的客观评估是实用的。