Doherty Patrick, Salman Ahmad, Furze Gill, Dalal Hasnain M, Harrison Alexander
Department of Health Sciences , University of York , York, North Yorkshire , UK.
Centre for Technology Enabled Health Research, Coventry University , Coventry, West Midlands , UK.
Open Heart. 2017 Jan 9;4(1):e000519. doi: 10.1136/openhrt-2016-000519. eCollection 2017.
To assess the extent by which programmes meet national minimum standards for the delivery of cardiac rehabilitation (CR) as part of the National Certification Programme for Cardiovascular Rehabilitation (NCP_CR).
The analysis used UK National Audit of Cardiac Rehabilitation (NACR) data extracted and validated for the period 2013-2014 set against six NCP_CR measures deemed as important for the delivery of high-quality CR programmes. Each programme that achieved a single minimum standard was given a score of 1. The range of the scoring for meeting the minimum standards is between 1 and 6. The performance of CR programmes was categorised into three groups: high (score of 5-6), middle (scores of 3-4) and low (scores of 1-2). If a programme did not meet any of the six criteria, they were considered to have failed.
Data from 170 CR programmes revealed statistically significant differences among UK CR programmes. The principal findings were that, based on NCP_CR criteria, 30.6% were assessed as high performance with 45.9% as mid-level performance programmes, 18.2% were in the lower-level and 5.3% failed to meet any of the minimum criteria.
This study shows that high levels of performance is achievable in the era of modern cardiology and that many CR programmes are close to meeting high performance standards. However, substantial variation, below the recommended minimum standards, exists throughout the UK. National certification should be seen as a positive step to ensure that patients, irrespective of where they live, are accessing quality services.
作为国家心血管康复认证计划(NCP_CR)的一部分,评估各项目符合心脏康复(CR)国家最低标准的程度。
该分析使用了英国心脏康复国家审计(NACR)在2013 - 2014年期间提取并验证的数据,对照六项被认为对提供高质量CR项目很重要的NCP_CR指标进行分析。每个达到单项最低标准的项目得1分。达到最低标准的得分范围在1至6分之间。CR项目的表现分为三组:高分(5 - 6分)、中分(3 - 4分)和低分(1 - 2分)。如果一个项目未达到六项标准中的任何一项,则被视为不合格。
170个CR项目的数据显示,英国的CR项目之间存在统计学上的显著差异。主要发现是,根据NCP_CR标准,30.6%被评估为高性能,45.9%为中等水平项目,18.2%处于低水平,5.3%未达到任何最低标准。
本研究表明,在现代心脏病学时代可以实现高水平的表现,并且许多CR项目接近达到高性能标准。然而,在整个英国,仍存在大量低于推荐最低标准的差异。国家认证应被视为确保患者无论居住何处都能获得优质服务的积极举措。