The whole-body iodine-131 scintigraphy is an imaging technique in monitoring patients with a history of thyroid cancer. Although the rate of false positives is negligible, it is not nonexistent. We report the case of an intervened and treated patient for thyroid cancer with good clinical and biochemical response. Scintigraphic findings were consistent with unsuspected bone metastasis. Fused SPECT/CT data allowed accurate diagnosis of giant diaphragmatic hernia associated with intrathoracic stomach, a very rare pathology that can lead to false positive results.

摘要

全身碘-131闪烁扫描是监测有甲状腺癌病史患者的一种成像技术。尽管假阳性率可忽略不计,但并非不存在。我们报告了一例接受干预和治疗的甲状腺癌患者,其临床和生化反应良好。闪烁扫描结果与未被怀疑的骨转移一致。融合的SPECT/CT数据准确诊断出与胸腔内胃相关的巨大膈疝,这是一种非常罕见的病理情况,可导致假阳性结果。