超声溶栓的一个未被发现的风险因素:超声透过人类颅骨时的大幅波动。

An uncovered risk factor of sonothrombolysis: Substantial fluctuation of ultrasound transmittance through the human skull.

作者信息

Wang Zuojun, Komatsu Teppei, Mitsumura Hidetaka, Nakata Norio, Ogawa Takeki, Iguchi Yasuyuki, Yokoyama Masayuki

机构信息

Division of Ultrasound Development and Application, The Jikei University School of Medicine, 3-25-8, Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan.

Department of Neurology, The Jikei University School of Medicine, 3-25-8, Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan.

出版信息

Ultrasonics. 2017 May;77:168-175. doi: 10.1016/j.ultras.2017.02.012. Epub 2017 Feb 16.

Abstract

Sonothrombolysis is one of the most feasible methods for enhancing clot lysis with a recombinant tissue plasminogen activator (rt-PA) in cases of acute ischemic strokes. For safe and efficient clinical practices of sonothrombolysis, accurate estimation of ultrasound transmittance through the human skull is critical. Previously, we reported substantial and periodic fluctuation of ultrasound transmittance through a bone-phantom plate following changes to ultrasound frequency, the thickness of the bone-phantom plate, and the distance between a transducer and the bone-phantom plate. In the present study, we clarify the transmittance behavior of medium-frequency ultrasound (from 400kHz to 600kHz) through the human skull, and examine reduction of the transmittance fluctuation. For the study, we measured transmittance of sinusoidal ultrasound waves at 400kHz, 500kHz, and 600kHz at 13 temple spots on 3 human skulls by changing the distance between a transducer and the skull bone, and found substantial and periodic fluctuation in the transmittance behaviors for these sinusoidal voltage excitations. Degrees of the fluctuation varied depending on the measurement spots. A fluctuation ratio between the maximum transmittance and the minimum transmittance reached 3 in some spots. This large transmittance fluctuation is considered to be a risk factor for sonothrombolysis therapies. We examined a modulated ultrasound wave to reduce the fluctuation, and succeeded in obtaining considerable reduction. The average fluctuation ratios for 400-kHz, 500-kHz, and 600-kHz waves were 2.38, 2.38, and 2.07, respectively. We successfully reduced the ratio to 1.72 by using a periodic selection of random frequency (PSRF)-type of modulation wave. The thus obtained results indicate that attention to the fluctuation in ultrasound transmittance through the skull is necessary for safe and effective sonothrombolysis therapies, and that modulated ultrasound waves constitute a powerful method for reducing the risk of fluctuation.

摘要

在急性缺血性中风病例中,超声溶栓是增强重组组织型纤溶酶原激活剂(rt-PA)溶栓效果最可行的方法之一。为了实现超声溶栓安全有效的临床应用,准确评估超声透过人类颅骨的透过率至关重要。此前,我们报道过,随着超声频率、骨模拟板厚度以及换能器与骨模拟板之间距离的变化,超声透过骨模拟板的透过率会出现大幅且周期性的波动。在本研究中,我们阐明了中频超声(400kHz至600kHz)透过人类颅骨的透过率行为,并研究了如何减少透过率波动。在这项研究中,我们通过改变换能器与颅骨之间的距离,测量了3个人类颅骨上13个颞部位置处400kHz、500kHz和600kHz正弦超声波的透过率,发现这些正弦电压激励的透过率行为存在大幅且周期性的波动。波动程度因测量位置而异。在某些位置,最大透过率与最小透过率之间的波动比达到了3。这种较大的透过率波动被认为是超声溶栓治疗的一个风险因素。我们研究了调制超声波以减少波动,并成功实现了显著降低。400kHz、500kHz和600kHz波的平均波动比分别为2.38、2.38和2.07。通过使用随机频率周期性选择(PSRF)型调制波,我们成功将该比例降低至1.72。由此获得的结果表明,对于安全有效的超声溶栓治疗,必须关注超声透过颅骨的透过率波动,并且调制超声波是降低波动风险的有力方法。