Suppr超能文献

机械负荷和表面粗糙度对硅橡胶和甲基丙烯酸酯基后牙复合材料磨损的影响。

Effect of Mechanical Loads and Surface Roughness on Wear of Silorane and Methacrylate-Based Posterior Composites.

作者信息

Tabatabaei Masomeh Hasani, Arami Sakineh, Farahat Farnaz

机构信息

Associate Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

Assistant Professor, Department of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

出版信息

J Dent (Tehran). 2016 Nov;13(6):407-414.

Abstract

OBJECTIVES

Dental composite wear in posterior restorations is a concern and is affected by different factors. This study was conducted to evaluate the effect of polishing and mechanical loads on wear of silorane-based and methyl methacrylate-based composites resins.

MATERIALS AND METHODS

Of each dental composite (Filtek P90 and Filtek P60), 40 samples were fabricated in a polyethylene mold (4mm diameter, 10mm height). According to the finishing and/or polishing protocols (180-grit or 2500-grit silicon carbide papers), the samples of each composite were divided into two groups. Surface roughness (R ) was measured and recorded using a contact profilometer. The weight of each sample was also measured in grams. The wear test was performed in a pin-on-disc device under two different loads (70N, 150N). Afterwards, samples were subjected to profilometry and their weight was measured again. Data were analyzed using t-test and univariate ANOVA. P <0.05 was considered statistically significant.

RESULTS

Higher mechanical load resulted in greater weight loss (P<0.001). Samples polished with 2500-grit papers showed significantly lower Ra changes compared to those polished with 180-grit papers (P<0.001). Filtek P90 had greater weight loss than Filtek P60 except in one condition (180-grit, 70N).

CONCLUSIONS

Results showed that wear of posterior composite restorations depends on mechanical load, type of composite resin and surface properties.

摘要

目的

后牙修复体中牙科复合材料的磨损是一个值得关注的问题,并且受到不同因素的影响。本研究旨在评估抛光和机械负荷对基于硅烷和基于甲基丙烯酸甲酯的复合树脂磨损的影响。

材料与方法

使用聚乙烯模具(直径4mm,高10mm)制作每种牙科复合材料(Filtek P90和Filtek P60)的40个样本。根据修整和/或抛光方案(180目或2500目碳化硅砂纸),将每种复合材料的样本分为两组。使用接触式轮廓仪测量并记录表面粗糙度(R )。每个样本的重量也以克为单位进行测量。磨损试验在销盘装置中于两种不同负荷(70N,150N)下进行。之后,对样本进行轮廓测量并再次测量其重量。使用t检验和单因素方差分析对数据进行分析。P<0.05被认为具有统计学意义。

结果

更高的机械负荷导致更大的重量损失(P<0.001)。与用180目砂纸抛光的样本相比,用2500目砂纸抛光的样本显示出明显更低的Ra变化(P<0.001)。除了一种情况(180目,70N)外,Filtek P90的重量损失比Filtek P60更大。

结论

结果表明,后牙复合修复体的磨损取决于机械负荷、复合树脂类型和表面特性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4798/5318497/9a5be037c367/JOD-13-407-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验