The aims of this study were to evaluate the effect of various finishing and polishing procedures on the surface roughness of six different composite resin materials (Artemis Enamel, TPH Spectrum, Filtek A-110, Filtek Supreme Enamel, Solitaire 2, and Filtek P-60) as well as to evaluate the effectiveness of the surface sealant application (BisCover) on the surface roughness after finishing and polishing procedures of tested composites.
Specimens (n=168) measuring 5 mm in diameter x 2 mm in thickness were fabricated in a plexiglass well covered with a Mylar strip using six composite resins. A control group of seven specimens of each material received no polishing after being cured under the Mylar strip. Twenty-one specimens for each composite were randomly divided among three finishing and polishing groups (n=7). Each group was polished using a different system: Carbide bur/Sof-Lex disc, Carbide bur/Enhance disc with polishing paste, and Carbide bur/Edenta composite finishing kit. The average surface roughness (Ra, microm) of the control and treated specimens were measured with the Mitutoyo Surftest-402 Surface Roughness tester. After a surface sealant (BisCover) was applied to all treated specimens, according to manufacturer's instructions, the average roughness (Ra) was measured again. Results were statistically analyzed using analysis of variance (ANOVA) and the post-hoc Scheffe's test at a p<0.05 significance level.
Significant differences were found for the surface roughness (p<0.05) with interaction among composite resins and the finishing systems used (p<0.05). Enhance/Biscover finishing and polishing procedure surface was not significantly different from the Mylar strip surface groups (p>0.05). The Mylar strip group was not significantly different from the Sof-Lex/BisCover and Edenta/BisCover groups. The ranking of mean Ra values by materials was as follows: Filtek Supreme Enamel < Filtek A110 < TPH Spectrum < Artemis <Filtek P-60 < Solitaire 2. The ranking of mean Ra values by polishing systems was as follows: Enhance/BisCover < Mylar Strip < Sof-Lex/BisCover < Edenta/BisCover < Sof-Lex < Enhance < Edenta.
Smoother surfaces were recorded for the Enhance/BisCover and the Mylar strip-formed surface groups. The composite finishing kit Edenta significantly increased the Ra for all tested composites (p<0.05). But after finishing with Edenta, the use of a surface sealant (BisCover) significantly improved the surface smoothness of all tested composites (p<0.05). Use of BisCover surface sealant on anterior and posterior resin composite restorations after finishing and polishing procedures is recommended.
本研究的目的是评估各种修整和抛光程序对六种不同复合树脂材料(Artemis Enamel、TPH Spectrum、Filtek A - 110、Filtek Supreme Enamel、Solitaire 2和Filtek P - 60)表面粗糙度的影响,以及评估在测试复合材料进行修整和抛光程序后,表面密封剂(BisCover)应用对表面粗糙度的效果。
使用六种复合树脂在覆盖有聚酯薄膜条的有机玻璃孔中制作直径5毫米×厚度2毫米的试样(n = 168)。每种材料的七个试样组成的对照组在聚酯薄膜条下固化后不进行抛光。每种复合材料的21个试样随机分为三个修整和抛光组(n = 7)。每组使用不同的系统进行抛光:硬质合金车针/ Sof - Lex盘、硬质合金车针/带抛光膏的Enhance盘以及硬质合金车针/ Edenta复合修整套件。使用Mitutoyo Surftest - 402表面粗糙度测试仪测量对照组和处理后试样的平均表面粗糙度(Ra,微米)。根据制造商说明,对所有处理后的试样施加表面密封剂(BisCover)后,再次测量平均粗糙度(Ra)。使用方差分析(ANOVA)和事后Scheffe检验在p < 0.05显著性水平对结果进行统计分析。
在复合树脂和所使用的修整系统之间的相互作用下,表面粗糙度存在显著差异(p < 0.05)。Enhance / Biscover修整和抛光程序表面与聚酯薄膜条表面组无显著差异(p > 0.05)。聚酯薄膜条组与Sof - Lex / BisCover和Edenta / BisCover组无显著差异。按材料的平均Ra值排名如下:Filtek Supreme Enamel < Filtek A110 < TPH Spectrum < Artemis < Filtek P - 6 < Solitaire 2。按抛光系统的平均Ra值排名如下:Enhance / BisCover < 聚酯薄膜条 < Sof - Lex / BisCover < Edenta / BisCover < Sof - Lex < Enhance < Edenta。
Enhance / BisCover和聚酯薄膜条形成的表面组记录到更光滑的表面。Edenta复合修整套件显著增加了所有测试复合材料的Ra(p < 0.05)。但使用Edenta修整后,表面密封剂(BisCover)的使用显著改善了所有测试复合材料的表面光滑度(p < 0.05)。建议在前后牙树脂复合修复体的修整和抛光程序后使用BisCover表面密封剂。