Suppr超能文献

尤因肉瘤行人工膝关节置换术后金属磨损导致的假肿瘤

Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma.

作者信息

Craig Richard, Vlychou Marianna, McCarthy Catherine L, Gibbons Christopher L M H, Athanasou N A

机构信息

Department of Orthopaedics, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK.

Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Department of Histopathology, Nuffield Orthopaedic Centre, University of Oxford, Oxford, OX3 7HE, UK.

出版信息

Skeletal Radiol. 2017 Jul;46(7):967-974. doi: 10.1007/s00256-017-2610-0. Epub 2017 Mar 7.

Abstract

Pseudotumours are well recognised as a complication of metal-on-metal hip arthroplasties and are thought to develop on the basis of an innate and adaptive immune response to cobalt-chrome (Co-Cr) wear particles. We report a case of a large pseudotumour that developed following a knee endoprosthetic replacement (EPR) undertaken for Ewing sarcoma. The lesion contained necrotic and degenerate connective tissue in which there were numerous scattered metal wear-containing macrophages, eosinophil polymorphs, lymphocytes, plasma cells and aseptic lymphocyte-dominated vascular-associated lesion-like lymphoid aggregates. Metal ion levels were elevated. No evidence of infection or tumour was noted and it was concluded that the lesion was most likely an inflammatory pseudotumour developing on the basis of an innate and adaptive immune response to components of Co-Cr metal wear derived from the knee EPR.

摘要

假肿瘤作为金属对金属髋关节置换术的一种并发症已广为人知,被认为是基于对钴铬(Co-Cr)磨损颗粒的先天性和适应性免疫反应而形成的。我们报告一例在因尤因肉瘤进行膝关节假体置换(EPR)后出现的大型假肿瘤病例。该病变包含坏死和退变的结缔组织,其中有许多散在的含金属磨损颗粒的巨噬细胞、嗜酸性多形核白细胞、淋巴细胞、浆细胞以及无菌性淋巴细胞为主的血管相关病变样淋巴样聚集物。金属离子水平升高。未发现感染或肿瘤的证据,得出的结论是该病变很可能是基于对膝关节EPR产生的Co-Cr金属磨损成分的先天性和适应性免疫反应而形成的炎性假肿瘤。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ad74/5438826/3fd8e6302235/256_2017_2610_Fig1_HTML.jpg

相似文献

1
Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma.
Skeletal Radiol. 2017 Jul;46(7):967-974. doi: 10.1007/s00256-017-2610-0. Epub 2017 Mar 7.
2
Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours.
J Bone Joint Surg Br. 2010 Mar;92(3):356-61. doi: 10.1302/0301-620X.92B3.23281.
4
Common peroneal nerve palsy associated with pseudotumour after total knee arthroplasty.
Knee. 2012 Mar;19(2):148-50. doi: 10.1016/j.knee.2011.02.002. Epub 2011 Apr 16.
6
The correlation of wear with histological features after failed hip resurfacing arthroplasty.
J Bone Joint Surg Am. 2013 Jun 19;95(12):e81. doi: 10.2106/JBJS.L.00775.
7
[Pseudotumour in metal-on-metal hip arthroplasty].
Ugeskr Laeger. 2013 Mar 11;175(11):735-6.
8
Asymptomatic pseudotumours after metal-on-metal hip resurfacing show little change within one year.
Bone Joint J. 2013 Dec;95-B(12):1626-31. doi: 10.1302/0301-620X.95B12.32248.
9
Mixing and matching causing taper wear: corrosion associated with pseudotumour formation.
J Bone Joint Surg Br. 2012 Feb;94(2):281-6. doi: 10.1302/0301-620X.94B2.27247.

引用本文的文献

1
Secondary Infection of Adverse Local Tissue Reaction Leading to Amputation in a Patient With a Modular Knee Endoprosthesis.
J Am Acad Orthop Surg Glob Res Rev. 2025 Mar 14;9(3). doi: 10.5435/JAAOSGlobal-D-24-00293. eCollection 2025 Mar 1.
2
Taper Junction Subsidence Occurs in Modular Tumor Endoprostheses: How Concerned Should We Be?
Clin Orthop Relat Res. 2025 Feb 1;483(2):289-302. doi: 10.1097/CORR.0000000000003205. Epub 2024 Aug 19.
3
Suspicion of Recurrent Osteosarcoma in a Patient with Pseudotumour Adjacent To the Endoprosthesis.
J Ultrason. 2022 Apr 27;22(89):140-143. doi: 10.15557/JoU.2022.0023. eCollection 2022 Apr.
4
Ultrasound evaluations and guided procedures of the painful joint arthroplasty.
Skeletal Radiol. 2022 Nov;51(11):2105-2120. doi: 10.1007/s00256-022-04080-y. Epub 2022 May 28.
6
Blood Metal Ion Release After Primary Total Knee Arthroplasty: A Prospective Study.
Orthop Surg. 2020 Apr;12(2):396-403. doi: 10.1111/os.12591. Epub 2020 Feb 5.

本文引用的文献

1
The pathobiology and pathology of aseptic implant failure.
Bone Joint Res. 2016 May;5(5):162-8. doi: 10.1302/2046-3758.55.BJR-2016-0086.
2
[Adverse reactions to metal orthopedic implants after knee arthroplasty].
Hautarzt. 2016 May;67(5):347-51. doi: 10.1007/s00105-016-3793-3.
4
Total Knee Arthroplasty Failure Induced by Metal Hypersensitivity.
Am J Case Rep. 2015 Aug 17;16:542-7. doi: 10.12659/AJCR.893609.
7
The association between metal allergy, total knee arthroplasty, and revision: study based on the Danish Knee Arthroplasty Register.
Acta Orthop. 2015 Jun;86(3):378-83. doi: 10.3109/17453674.2014.999614. Epub 2015 Jan 13.
8
Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses.
Biomed Res Int. 2014;2014:817257. doi: 10.1155/2014/817257. Epub 2014 Sep 8.
9
Metal sensitivities among TJA patients with post-operative pain: indications for multi-metal LTT testing.
J Long Term Eff Med Implants. 2014;24(1):37-44. doi: 10.1615/jlongtermeffmedimplants.2014010261.
10
Total knee arthroplasty in patients with hypersensitivity to metals.
Int Orthop. 2014 Feb;38(2):329-33. doi: 10.1007/s00264-013-2229-2. Epub 2014 Jan 4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验