Suppr超能文献

多发性硬化症患者客观身体活动测量:文献综述

Objective physical activity measurement in people with multiple sclerosis: a review of the literature.

作者信息

Casey Blathin, Coote Susan, Donnelly Alan

机构信息

a Department of Clinical Therapies, Faculty of Education and Health Sciences , University of Limerick , Limerick , Ireland.

b Department of Physical Education and Sport Sciences, Faculty of Education and Health Sciences , University of Limerick , Limerick , Ireland.

出版信息

Disabil Rehabil Assist Technol. 2018 Feb;13(2):124-131. doi: 10.1080/17483107.2017.1297859. Epub 2017 Mar 13.

Abstract

PURPOSE

The purpose of this study is to identify the objective physical activity (PA) measurement tools and outputs that are used within Multiple Sclerosis (MS) literature.

METHODS

A systematic search strategy on eight databases (2000-2016) using keywords associated with MS and PA.

RESULTS

This review includes 32 papers. Uni-axial accelerometers were the most popular objective PA tool in this review (68%). Pedometers (14%) and multi-sensor systems (3%) were the second and third most common. PA outputs included activity counts per day, steps per day, energy expenditure per day, minutes of moderate-vigorous PA (MVPA), minutes of light PA and daily dynamic activity. Both activity counts per day (n = 21 studies), and steps per day (n = 11 studies) were most commonly used representing 78%.

CONCLUSION

Uni-axial accelerometers and pedometers are the most popular PA measurement tools used in MS literature. However, developments in the field mean that most new sensors are tri-axial, and multi-sensor systems are also available. Researchers should use devices with published validation information, and should utilize the detail on activity patterns available from accelerometer measurement instead of expressing a single unit such as activity counts or step counts per day. Attention to capturing the duration, frequency, intensity and energy expended during daily PA is warranted. Implications for Rehabilitation The review reports that accelerometers were the research tool most frequently reported in the literature, though there were differences in device type and in how activity data was extracted from the stored information. The majority of research studies of physical activity levels in Multiple Sclerosis fail to provide an adequate range of activity outcomes, frequently using outcomes which do not allow simple cross-comparisons with other populations.

摘要

目的

本研究旨在确定多发性硬化症(MS)文献中使用的客观身体活动(PA)测量工具及结果。

方法

在八个数据库(2000 - 2016年)中使用与MS和PA相关的关键词进行系统检索。

结果

本综述纳入32篇论文。单轴加速度计是本综述中最常用的客观PA工具(68%)。计步器(14%)和多传感器系统(3%)分别位列第二和第三。PA结果包括每日活动计数、每日步数、每日能量消耗、中度至剧烈身体活动(MVPA)分钟数、轻度PA分钟数和每日动态活动。每日活动计数(n = 21项研究)和每日步数(n = 11项研究)最为常用,占78%。

结论

单轴加速度计和计步器是MS文献中最常用的PA测量工具。然而,该领域的发展意味着大多数新传感器是三轴的,并且多传感器系统也已出现。研究人员应使用具有已发表验证信息的设备,并应利用加速度计测量中可得的活动模式细节,而非仅表达单个单位,如每日活动计数或步数。有必要关注捕捉日常PA期间的持续时间、频率、强度和消耗的能量。对康复的启示 该综述报告称,加速度计是文献中最常报道的研究工具,不过在设备类型以及如何从存储信息中提取活动数据方面存在差异。大多数关于多发性硬化症身体活动水平的研究未能提供足够范围的活动结果,经常使用无法与其他人群进行简单交叉比较的结果。