Suppr超能文献

局部血压(静水压力变化)背景下外部生理参数对光电容积脉搏波信号影响的实验研究。

An Experimental Study of the Effects of External Physiological Parameters on the Photoplethysmography Signals in the Context of Local Blood Pressure (Hydrostatic Pressure Changes).

机构信息

Optical Fibre Sensors Research Centre, Department of Electronic & Computer Engineering, University of Limerick, Limerick V94 T9PX, Ireland.

出版信息

Sensors (Basel). 2017 Mar 10;17(3):556. doi: 10.3390/s17030556.

Abstract

A comprehensive study of the effect of a wide range of controlled human subject motion on Photoplethysmographic signals is reported. The investigation includes testing of two separate groups of 5 and 18 subjects who were asked to undertake set exercises whilst simultaneously monitoring a wide range of physiological parameters including Breathing Rate, Heart Rate and Localised Blood Pressure using commercial clinical sensing systems. The unique finger mounted PPG probe equipped with miniature three axis accelerometers for undertaking this investigation was a purpose built in-house version which is designed to facilitate reproducible application to a wide range of human subjects and the study of motion. The subjects were required to undertake several motion based exercises including standing, sitting and lying down and transitions between these states. They were also required to undertake set arm movements including arm-swinging and wrist rotation. A comprehensive set of experimental results corresponding to all motion inducing exercises have been recorded and analysed including the baseline (BL) value (DC component) and the amplitude of the oscillation of the PPG. All physiological parameters were also recorded as a simultaneous time varying waveform. The effects of the motion and specifically the localised Blood Pressure (BP) have been studied and related to possible influences of the Autonomic Nervous System (ANS) and hemodynamic pressure variations. It is envisaged that a comprehensive study of the effect of motion and the localised pressure fluctuations will provide valuable information for the future minimisation of motion artefact effect on the PPG signals of this probe and allow the accurate assessment of total haemoglobin concentration which is the primary function of the probe.

摘要

本文全面研究了广泛的受控人体运动对光电容积脉搏波信号的影响。该研究包括对两组 5 人和 18 人进行测试,要求他们在同时监测呼吸频率、心率和局部血压等广泛的生理参数的同时进行设定的运动,使用商业临床传感系统。用于进行这项研究的独特的手指佩戴式 PPG 探头配备了微型三轴加速度计,是专门为促进对广泛的人体和运动研究的可重复应用而设计的。要求受试者进行几种基于运动的练习,包括站立、坐下和躺下以及这些状态之间的转换。他们还需要进行设定的手臂运动,包括手臂摆动和手腕旋转。已经记录并分析了与所有运动诱导练习相对应的一整套实验结果,包括基线(BL)值(直流分量)和 PPG 的振荡幅度。所有生理参数也被记录为同时变化的波形。研究了运动的影响,特别是局部血压(BP)的影响,并将其与自主神经系统(ANS)和血液动力学压力变化的可能影响联系起来。预计对运动和局部压力波动影响的全面研究将为未来最小化该探头的运动伪影对 PPG 信号的影响提供有价值的信息,并允许对探头的主要功能——总血红蛋白浓度进行准确评估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/afb3/5375842/7f737122456f/sensors-17-00556-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验