To investigate the effects of spatial separation and noise type on sentence recognition by unilateral Mandarin-speaking cochlear implant (CI) users and normal-hearing (NH) listeners.
Twenty-two unilateral Mandarin-speaking CI users and six NH listeners participated in this study. Speech reception thresholds were measured for three noise types (steady state noise, speech babble, and music). Sentences from the Mandarin Speech Perception test were presented directly in front of the listener (0°). Noise was presented from one of the five speaker locations: -90°, -45°, 0°, +45°, and +90°.
Overall, CI performance was significantly poorer than NH performance for all spatial separation and noise type conditions. NH listeners performed best with music and poorest with steady noise. CI users performed best with steady noise, and poorest with babble. Performance was significantly affected by noise location and noise type. There was no significant difference in head shadow effects among the different noise types for CI users.
Performance was much poorer in CI than in NH listeners for all noise types and spatial separations. Noise type differently affected unilateral CI users and NH listeners. The limited spectral resolution in CI users did not appear to affect head shadow.
研究空间分离和噪声类型对单侧使用普通话的人工耳蜗(CI)使用者和听力正常(NH)听众句子识别的影响。
22名单侧使用普通话的CI使用者和6名NH听众参与了本研究。测量了三种噪声类型(稳态噪声、言语嘈杂声和音乐)下的言语接受阈值。普通话言语感知测试中的句子直接在听众正前方(0°)呈现。噪声从五个扬声器位置之一呈现:-90°、-45°、0°、+45°和+90°。
总体而言,在所有空间分离和噪声类型条件下,CI使用者的表现明显比NH听众差。NH听众在音乐环境中表现最佳,在稳态噪声环境中表现最差。CI使用者在稳态噪声环境中表现最佳,在言语嘈杂声环境中表现最差。表现受到噪声位置和噪声类型的显著影响。CI使用者在不同噪声类型之间的头影效应没有显著差异。
对于所有噪声类型和空间分离情况,CI使用者的表现远不如NH听众。噪声类型对单侧CI使用者和NH听众的影响不同。CI使用者有限的频谱分辨率似乎并未影响头影效应。