Suppr超能文献

低剂量与标准剂量CT诊断急性阑尾炎的比较:一项Meta分析

Comparison of Low- and Standard-Dose CT for the Diagnosis of Acute Appendicitis: A Meta-Analysis.

作者信息

Yun Seong Jong, Ryu Chang-Woo, Choi Na Young, Kim Hyun Cheol, Oh Ji Young, Yang Dal Mo

机构信息

1 Department of Medicine, Graduate School, Kyung Hee University, Dongdaemun-gu, Seoul, Republic of Korea.

2 Department of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, 892 Dongnam-ro, Gangdong-Gu, Seoul 134-727, Republic of Korea.

出版信息

AJR Am J Roentgenol. 2017 Jun;208(6):W198-W207. doi: 10.2214/AJR.16.17274. Epub 2017 Mar 16.

Abstract

OBJECTIVE

A meta-analysis was performed to compare low-dose CT and standard-dose CT in the diagnosis of acute appendicitis with an emphasis on diagnostic value.

MATERIALS AND METHODS

A systematic literature search for articles published through June 2016 was performed to identify studies that compared low-dose CT with standard-dose CT for the evaluation of patients suspected of having acute appendicitis. Summary estimates of sensitivity and specificity with 95% CIs were calculated using a bivariate random-effects model. Meta-regression was used to perform statistical comparisons of low-dose CT and standard-dose CT.

RESULTS

Of 154 studies, nine studies investigating a total of 2957 patients were included in this meta-analysis. The pooled sensitivity and specificity of low-dose CT were 96.25% (95% CI, 91.88-98.31%) and 93.22% (95% CI, 88.75-96.00%), respectively. The pooled sensitivity and specificity of standard-dose CT were 96.40% (95% CI, 93.55-98.02%) and 92.17% (95% CI, 88.24-94.86%), respectively. In a joint model estimation of meta-regression, lowand standard-dose CT did not show a statistically significant difference (p = 0.71). Both lowand standard-dose CT seem to be characterized by high positive and negative predictive values across a broad spectrum of pretest probabilities for acute appendicitis.

CONCLUSION

Low-dose CT is highly effective for the diagnosis of suspected appendicitis and can be considered a valid alternative first-line imaging test that reduces the potential risk of exposure to ionizing radiation.

摘要

目的

进行一项荟萃分析,比较低剂量CT和标准剂量CT在急性阑尾炎诊断中的应用,重点关注诊断价值。

材料与方法

对截至2016年6月发表的文章进行系统文献检索,以确定比较低剂量CT与标准剂量CT评估疑似急性阑尾炎患者的研究。使用双变量随机效应模型计算敏感性和特异性的汇总估计值及95%置信区间。采用Meta回归对低剂量CT和标准剂量CT进行统计学比较。

结果

在154项研究中,本荟萃分析纳入了9项研究,共涉及2957例患者。低剂量CT的合并敏感性和特异性分别为96.25%(95%置信区间,91.88 - 98.31%)和93.22%(95%置信区间,88.75 - 96.00%)。标准剂量CT的合并敏感性和特异性分别为96.40%(95%置信区间,93.55 - 98.02%)和92.17%(95%置信区间,88.24 - 94.86%)。在Meta回归的联合模型估计中,低剂量CT和标准剂量CT未显示出统计学显著差异(p = 0.71)。对于急性阑尾炎的广泛预测试概率范围,低剂量CT和标准剂量CT似乎都具有较高的阳性和阴性预测值。

结论

低剂量CT对疑似阑尾炎的诊断非常有效,可被视为一种有效的替代一线成像检查,可降低电离辐射暴露的潜在风险。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验