儿童和成人疑似阑尾炎患者低剂量 CT 的诊断性能:系统评价和诊断荟萃分析。

The diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients: A systematic review and diagnostic meta-analysis.

机构信息

Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-Ro, Songpa-Gu, Seoul, 05505, Republic of Korea.

Department of Radiology, Namwon Medical Center, 365, Chungjeong-ro, Namwon-si, Jeollabuk-do, 590-702, Republic of Korea.

出版信息

Eur Radiol. 2018 Jun;28(6):2537-2548. doi: 10.1007/s00330-017-5231-z. Epub 2018 Jan 11.

Abstract

OBJECTIVE

To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis.

METHODS

A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed.

RESULTS

Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT.

CONCLUSION

Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis.

KEY POINTS

• Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.

摘要

目的

评估疑似阑尾炎的低剂量 CT 的诊断性能。

方法

通过系统检索 MEDLINE 和 EMBASE 数据库,检索时间截至 2017 年 1 月 10 日。选择评估小儿和成人疑似阑尾炎的低剂量 CT 诊断性能的研究。使用分层逻辑回归模型计算汇总敏感性和特异性的汇总估计值。进行荟萃回归分析。

结果

纳入 14 项原始研究,共 3262 例患者。对于所有使用低剂量 CT 的研究,汇总敏感性为 96%(95%CI 93-98),汇总特异性为 94%(95%CI 92-95)。对于 11 项提供低剂量 CT 与标准剂量 CT 头对头比较的研究,低剂量 CT 的汇总敏感性为 96%(95%CI 91-98),特异性为 94%(95%CI 93-96),差异无统计学意义(p=.41)。荟萃回归分析中,没有影响异质性的显著因素。低剂量 CT 的中位有效辐射剂量为 1.8 mSv(1.46-4.16 mSv),与标准剂量 CT 相比,有效辐射剂量降低了 78%。

结论

低剂量 CT 对疑似阑尾炎具有出色的诊断性能。

关键点

  1. 低剂量 CT 对评估疑似阑尾炎具有出色的诊断性能。

  2. 低剂量 CT 与标准剂量 CT 的诊断性能相当。

  3. 低剂量 CT 的中位有效辐射剂量为 1.8 mSv(1.46-4.16)。

  4. 与标准剂量 CT 相比,低剂量 CT 降低了 78%的剂量。