疑似小头畸形胎儿中超声与磁共振成像测量胎儿头部生物指标的差异

Discrepancy in fetal head biometry between ultrasound and MRI in suspected microcephalic fetuses.

作者信息

Yaniv Gal, Katorza Eldad, Tsehmaister Abitbol Vered, Eisenkraft Arik, Bercovitz Ronen, Bader Salim, Hoffmann Chen

机构信息

1 Department of Diagnostic Imaging, Sheba Medical Center, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.

2 Department of Obstetrics and Gynecology, Sheba Medical Center, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.

出版信息

Acta Radiol. 2017 Dec;58(12):1519-1527. doi: 10.1177/0284185117698865. Epub 2017 Mar 17.

Abstract

Background Microcephaly is one of the most common fetal structural abnormalities, and prenatal microcephaly is considered a group I malformation of cortical development diagnosed according to ultrasound (US) skull measurements. Purpose To evaluate the agreement between fetal head US and magnetic resonance imaging (MRI) biometric measurements of suspected microcephalic fetuses. Material and Methods This institutional review board-approved retrospective study with waived informed consent included 180 pregnant women and was conducted at our medical center from March 2011 to April 2013. Biparietal diameter (BPD) and occipitofrontal diameter (OFD) results of fetal head US normograms were compared to normograms for MRI. We used Pearson and Spearman rho non-parametric correlation coefficients to assess the association between two quantitative variables, paired t-test for paired quantitative variables, and McNemar test for paired qualitative variables. Results The average BPD but not the average OFD percentiles in fetal head US differed significantly from the MRI results ( P < 0.0001). When looking at the accepted microcephaly threshold, both BPD and OFD percentiles differed significantly from MRI ( P < 0.0001 and P < 0.004, respectively). There was no correlation between US-measured skull biometry and MRI-measured brain biometry. Estimated cerebrospinal fluid volumes were significantly lower in the study group compared to 120 fetuses with normal findings in prenatal head US and MRI. Also, we have created a MRI-based normogram of fetal head circumference and gestational age. Conclusion The diagnosis of microcephaly by US alone may be insufficient and ideally should be validated by MRI before a final diagnosis is established.

摘要

背景

小头畸形是最常见的胎儿结构异常之一,产前小头畸形被认为是根据超声(US)颅骨测量诊断的皮质发育I组畸形。目的:评估疑似小头畸形胎儿的胎儿头部超声与磁共振成像(MRI)生物测量之间的一致性。材料与方法:本机构审查委员会批准的回顾性研究,豁免了知情同意,纳入了180名孕妇,于2011年3月至2013年4月在我们的医疗中心进行。将胎儿头部超声标准曲线的双顶径(BPD)和枕额径(OFD)结果与MRI标准曲线进行比较。我们使用Pearson和Spearman rho非参数相关系数评估两个定量变量之间的关联,使用配对t检验评估配对定量变量,使用McNemar检验评估配对定性变量。结果:胎儿头部超声的平均BPD百分位数与MRI结果有显著差异,但平均OFD百分位数无显著差异(P < 0.0001)。当查看公认的小头畸形阈值时,BPD和OFD百分位数与MRI均有显著差异(分别为P < 0.0001和P < 0.004)。超声测量的颅骨生物测量与MRI测量的脑生物测量之间无相关性。与产前头部超声和MRI检查结果正常的120例胎儿相比,研究组的估计脑脊液体积显著更低。此外,我们创建了基于MRI的胎儿头围和孕周标准曲线。结论:仅通过超声诊断小头畸形可能不足,理想情况下在最终诊断确立之前应由MRI进行验证。