Suppr超能文献

单脉冲和双脉冲经颅磁刺激评估膝伸肌功能的可靠性

Reliability of single- and paired-pulse transcranial magnetic stimulation for the assessment of knee extensor muscle function.

作者信息

Temesi John, Ly Sandy N, Millet Guillaume Y

机构信息

Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.

Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.

出版信息

J Neurol Sci. 2017 Apr 15;375:442-449. doi: 10.1016/j.jns.2017.02.037. Epub 2017 Feb 16.

Abstract

This study examined inter-session and intra-session transcranial magnetic stimulation (TMS) reliability at two test stimulus intensities in the knee extensors. Strong and weak TMS was delivered via single- and paired- (3-ms and 100-ms inter-stimulus interval) pulses on the same day and different days. All stimuli were delivered during isometric contractions of the knee extensors at 20% of maximal voluntary force. Motor-evoked potentials (MEP) were assessed in quadriceps femoris muscles. Relative (intra-class correlation coefficient, ICC) and absolute (standard error of measurement, SEM) reliability and variability (coefficient of variation) were assessed. MEPs elicited by strong and weak single-pulse TMS had excellent relative reliability in all muscles as did weak short-interval and strong long-interval paired-pulse TMS (all ICC>0.75). Conversely, relative reliability of strong short-interval and weak long-interval paired-pulse TMS was lower (ICC: 0.34-0.83 and 0.22-0.97, respectively). MEP size variability was lower (P<0.05) and SEM comparable or lower in strong compared to weak TMS conditions. These results suggest single- and paired-pulse TMS at both strong and weak intensities are generally reliable in the knee extensors. Strong (or both strong and weak) single-pulse TMS is recommended. The results indicate using weak test pulses for short-interval and strong test pulses for long-interval paired-pulse TMS are recommended.

摘要

本研究在两种测试刺激强度下,检验了膝关节伸肌的不同时段间和同时段内经颅磁刺激(TMS)的可靠性。在同一天及不同日期,通过单脉冲和双脉冲(刺激间隔为3毫秒和100毫秒)施加强TMS和弱TMS。所有刺激均在膝关节伸肌以最大自主力量的20%进行等长收缩时施加。在股四头肌中评估运动诱发电位(MEP)。评估了相对(组内相关系数,ICC)和绝对(测量标准误差,SEM)可靠性及变异性(变异系数)。强单脉冲和弱单脉冲TMS诱发的MEP在所有肌肉中均具有出色的相对可靠性,弱短间隔和强长间隔双脉冲TMS诱发的MEP也具有出色的相对可靠性(所有ICC>0.75)。相反,强短间隔和弱长间隔双脉冲TMS的相对可靠性较低(ICC分别为0.34 - 0.83和0.22 - 0.97)。与弱TMS条件相比,强TMS条件下MEP大小变异性更低(P<0.05),且SEM相当或更低。这些结果表明,强、弱强度的单脉冲和双脉冲TMS在膝关节伸肌中通常是可靠的。建议使用强(或强、弱)单脉冲TMS。结果表明,对于短间隔双脉冲TMS建议使用弱测试脉冲,对于长间隔双脉冲TMS建议使用强测试脉冲。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验