Suppr超能文献

内部生物素-抗生物素蛋白破伤风IgG酶联免疫吸附测定(ELISA)与检测低水平抗体的金标准体内小鼠中和试验的比较。

Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

作者信息

Sonmez Cemile, Coplu Nilay, Gozalan Aysegul, Akin Lutfu, Esen Berrin

机构信息

Public Health Institution of Turkey, Microbiology Reference Laboratories, Ankara, Turkey.

Diskapi Yildirim Beyazit Training and Research Hospital, Medical Microbiology Department, Ankara, Turkey.

出版信息

J Immunol Methods. 2017 Jun;445:67-70. doi: 10.1016/j.jim.2017.03.012. Epub 2017 Mar 18.

Abstract

BACKGROUND

Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml.

METHODS

A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml).

RESULTS

A statistically significant correlation (r=0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%.

CONCLUSION

In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected.

摘要

背景

检测抗破伤风抗体水平对于确定个体免疫状态以及制定预防措施都很有必要。酶联免疫吸附测定(ELISA)是体外检测中首选的方法,然而它可能会受到交叉反应抗体的影响。之前研发的一种内部ELISA检测方法被发现对于抗体水平≤1.0IU/ml时不可靠。于是开发了一种新方法来准确检测低抗体水平。本研究的目的是比较新开发的内部生物素-抗生物素蛋白破伤风IgG ELISA检测方法与体内小鼠中和试验在检测抗体水平≤1.0IU/ml时的结果。

方法

通过体内小鼠中和试验检测出的54份抗体水平处于三个不同水平(=0.01IU/ml、0.01 - 0.1IU/ml、0.1 - 1IU/ml)的血清样本,采用新开发的内部生物素-抗生物素蛋白破伤风IgG ELISA检测方法进行研究。使用五种不同浓度(0.01IU/ml、0.06IU/ml、0.2IU/ml、0.5IU/ml、1.0IU/ml)对该检测进行验证。

结果

观察到体内小鼠中和试验与内部生物素-抗生物素蛋白破伤风IgG ELISA检测方法之间存在统计学上的显著相关性(r = 0.9967,p = 0.001)。对于所测试的浓度,批内、批间、准确度、灵敏度、特异性和变异系数均确定为≤15%。

结论

对于检测水平≤1.0IU/ml,内部生物素-抗生物素蛋白破伤风IgG ELISA检测方法可以作为体内小鼠中和方法的替代方法。通过使用内部生物素-抗生物素蛋白破伤风IgG ELISA检测方法,能够可靠地检测出抗体水平未达保护水平的个体。