Suppr超能文献

用于肝脏纤维化分期实际临床应用的Supersonic Aixplorer剪切波弹性成像截断值的验证

Validation of Shear Wave Elastography Cutoff Values on the Supersonic Aixplorer for Practical Clinical Use in Liver Fibrosis Staging.

作者信息

Dhyani Manish, Grajo Joseph R, Bhan Atul K, Corey Kathleen, Chung Raymond, Samir Anthony E

机构信息

Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.

Department of Radiology, Division of Abdominal Imaging, University of Florida College of Medicine, Gainesville, Florida, USA.

出版信息

Ultrasound Med Biol. 2017 Jun;43(6):1125-1133. doi: 10.1016/j.ultrasmedbio.2017.01.022. Epub 2017 Mar 22.

Abstract

The purpose of this study was to determine the validity of previously established ultrasound shear wave elastography (SWE) cut-off values (≥F2 fibrosis) on an independent cohort of patients with chronic liver disease. In this cross-sectional study, approved by the institutional review board and compliant with the Health Insurance Portability and Accountability Act, 338 patients undergoing liver biopsy underwent SWE using an Aixplorer ultrasound machine (SuperSonic Imagine, Aix-en-Provence, France). Median SWE values were calculated from sets of 10 elastograms. A single blinded pathologist evaluated METAVIR fibrosis staging as the gold standard. The study analyzed 277 patients with a mean age of 48 y. On pathologic examination, 212 patients (76.5%) had F0-F1 fibrosis, whereas 65 (23.5%) had ≥F2 fibrosis. Spearman's correlation of fibrosis with SWE was 0.456 (p < 0.001). A cut-off value of 7.29 kPa yielded sensitivity of 95.4% and specificity of 50.5% for the diagnosis of METAVIR stage ≥F2 liver fibrosis in patients with liver disease using the SuperSonic Imagine Aixplorer SWE system.

摘要

本研究的目的是在一组独立的慢性肝病患者中确定先前建立的超声剪切波弹性成像(SWE)临界值(≥F2纤维化)的有效性。在这项经机构审查委员会批准并符合《健康保险流通与责任法案》的横断面研究中,338例接受肝活检的患者使用Aixplorer超声仪(法国普罗旺斯地区艾克斯市的SuperSonic Imagine公司)进行了SWE检查。从10幅弹性图集中计算出SWE值的中位数。由一名单盲病理学家将METAVIR纤维化分期作为金标准进行评估。该研究分析了277例平均年龄为48岁的患者。经病理检查,212例患者(76.5%)有F0 - F1纤维化,而65例(23.5%)有≥F2纤维化。纤维化与SWE的Spearman相关性为0.456(p < 0.001)。对于使用SuperSonic Imagine Aixplorer SWE系统诊断肝病患者的METAVIR≥F2期肝纤维化,7.29 kPa的临界值产生的敏感度为95.4%,特异度为50.5%。

相似文献

1
Validation of Shear Wave Elastography Cutoff Values on the Supersonic Aixplorer for Practical Clinical Use in Liver Fibrosis Staging.
Ultrasound Med Biol. 2017 Jun;43(6):1125-1133. doi: 10.1016/j.ultrasmedbio.2017.01.022. Epub 2017 Mar 22.
2
Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease.
J Ultrasound Med. 2019 Jan;38(1):103-111. doi: 10.1002/jum.14668. Epub 2018 May 15.
4
Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study.
Hepatology. 2012 Dec;56(6):2125-33. doi: 10.1002/hep.25936. Epub 2012 Aug 31.
8
Feasibility study for assessing liver fibrosis in paediatric and adolescent patients using real-time shear wave elastography.
J Med Imaging Radiat Oncol. 2015 Dec;59(6):687-94; quiz 751. doi: 10.1111/1754-9485.12388. Epub 2015 Oct 27.
10
Assessing Hepatic Fibrosis Using 2-D Shear Wave Elastography in Patients with Liver Tumors: A Prospective Single-Center Study.
Ultrasound Med Biol. 2017 Nov;43(11):2522-2529. doi: 10.1016/j.ultrasmedbio.2017.07.003. Epub 2017 Aug 12.

引用本文的文献

1
Characterizing dispersion in bovine liver using ARFI-based shear wave rheometry.
Biomed Phys Eng Express. 2024 Aug 30;10(5). doi: 10.1088/2057-1976/ad6b31.
4
Shear-wave elastography for evaluation of hepatic stiffness in chronic viral hepatitis B and C.
Clin Exp Hepatol. 2023 Jun;9(2):179-186. doi: 10.5114/ceh.2023.129112. Epub 2023 Jun 30.
7
Evaluation of thyroid nodules by shear wave elastography: a review of current knowledge.
J Endocrinol Invest. 2021 Oct;44(10):2043-2056. doi: 10.1007/s40618-021-01570-z. Epub 2021 Apr 16.
8
Can measuring passive neck muscle stiffness in whiplash injury patients help detect false whiplash claims?
Wien Klin Wochenschr. 2020 Sep;132(17-18):506-514. doi: 10.1007/s00508-020-01631-y. Epub 2020 Mar 18.
10
Objective Liver Fibrosis Estimation from Shear Wave Elastography.
Annu Int Conf IEEE Eng Med Biol Soc. 2018 Jul;2018:1-5. doi: 10.1109/EMBC.2018.8513011.

本文引用的文献

1
Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
Ultraschall Med. 2016 Feb;37(1):1-5. doi: 10.1055/s-0035-1567037. Epub 2016 Feb 12.
2
Diagnostic Accuracy of SuperSonic Shear Imaging for Staging of Liver Fibrosis: A Meta-analysis.
J Ultrasound Med. 2016 Feb;35(2):329-39. doi: 10.7863/ultra.15.03032.
3
Amyloidosis of the liver on shear wave elastography: case report and review of literature.
Abdom Imaging. 2015 Oct;40(8):3078-83. doi: 10.1007/s00261-015-0519-4.
5
Two-dimensional shear-wave elastography and conventional US: the optimal evaluation of liver fibrosis and cirrhosis.
Radiology. 2015 Apr;275(1):290-300. doi: 10.1148/radiol.14140828. Epub 2015 Jan 7.
8
Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography.
J Hepatol. 2015 Feb;62(2):317-24. doi: 10.1016/j.jhep.2014.09.020. Epub 2014 Sep 22.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验