Goldstein S, Michel C, Bors W, Saran M, Czapski G
Department of Physical Chemistry, Hebrew University of Jerusalem, Israel.
Free Radic Biol Med. 1988;4(5):295-303. doi: 10.1016/0891-5849(88)90050-0.
We have compared the direct method of pulse radiolysis to the indirect methods of cytochrome c and nitroblue tetrazolium for assaying the superoxide dismutase activity of a compound. We have shown that with pulse radiolysis, where high concentrations of O2- are generated, the "turnover" rate constant, kcat, can be determined directly, while with the indirect methods, where relatively low steady state concentrations of O2- are formed, the value of kcat determined by these methods, can be orders of magnitude lower than that determined directly. The main reason for the lower values obtained with the indirect methods is due to the fast reoxidation of the reduced compound by molecular oxygen. Additional problems which arise with the use of indirect methods for determining superoxide dismutase catalytic activity are discussed.
我们已将脉冲辐解的直接方法与用于测定化合物超氧化物歧化酶活性的细胞色素c和硝基蓝四唑的间接方法进行了比较。我们已经表明,在脉冲辐解中,会产生高浓度的O2-,“周转”速率常数kcat可以直接测定,而在间接方法中,会形成相对较低的O2-稳态浓度,通过这些方法测定的kcat值可能比直接测定的值低几个数量级。间接方法获得较低值的主要原因是还原态化合物被分子氧快速再氧化。还讨论了使用间接方法测定超氧化物歧化酶催化活性时出现的其他问题。