Suppr超能文献

使用免疫比浊法验证并确定犬糖化血红蛋白(HbA1c)的参考区间。

Validation and determination of a reference interval for canine HbA1c using an immunoturbidimetric assay.

作者信息

Goemans Anne F, Spence Susanna J, Ramsey Ian K

机构信息

Small Animal Hospital, University of Glasgow, Glasgow, UK.

出版信息

Vet Clin Pathol. 2017 Jun;46(2):227-237. doi: 10.1111/vcp.12477. Epub 2017 Apr 7.

Abstract

BACKGROUND

Hemoglobin A1c (HbA1c) provides a reliable measure of glycemic control over 2-3 months in human diabetes mellitus. In dogs, presence of HbA1c has been demonstrated, but there are no validated commercial assays.

OBJECTIVE

The purpose of the study was to validate a commercially available automated immunoturbidimetric assay for canine HbA1c and determine an RI in a hospital population.

METHODS

The specificity of the assay was assessed by inducing glycosylation in vitro using isolated canine hemoglobin, repeatability by measuring canine samples 5 times in succession, long term inter-assay imprecision by measuring supplied control materials, stability using samples stored at 4°C over 5 days and -20°C over 8 weeks, linearity by mixing samples of known HbA1c in differing proportions, and the effect of anticoagulants with paired samples. An RI was determined using EDTA-anticoagulated blood samples from 60 nondiabetic hospitalized animals of various ages and breeds. Hemoglobin A1c was also measured in 10 diabetic dogs.

RESULTS

The concentration of HbA1c increased proportionally with glucose concentration in vitro. For repeat measurements, the CV was 4.08% (range 1.16-6.10%). Samples were stable for 5 days at 4°C. The assay was linear within the assessed range. Heparin- and EDTA-anticoagulated blood provided comparable results. The RI for HbA1c was 9-18.5 mmol/mol. There was no apparent effect of age or breed on HbA1c. In diabetic dogs, HbA1c ranged from 14 to 48 mmol/mol.

CONCLUSIONS

The assay provides a reliable method for canine HbA1c measurement with good analytic performance.

摘要

背景

糖化血红蛋白A1c(HbA1c)可可靠地衡量人类糖尿病患者2至3个月内的血糖控制情况。在犬类中,已证实存在HbA1c,但尚无经过验证的商业检测方法。

目的

本研究旨在验证一种用于犬HbA1c的市售自动免疫比浊法,并确定医院群体中的参考区间(RI)。

方法

通过使用分离的犬血红蛋白在体外诱导糖基化来评估该检测方法的特异性,通过连续5次测量犬类样本评估重复性,通过测量提供的对照材料评估长期批间不精密度,通过将样本在4°C下储存5天和在-20°C下储存8周来评估稳定性,通过以不同比例混合已知HbA1c的样本评估线性,以及使用配对样本评估抗凝剂的影响。使用来自60只不同年龄和品种的非糖尿病住院动物的乙二胺四乙酸(EDTA)抗凝血液样本确定参考区间。还对10只糖尿病犬测量了HbA1c。

结果

体外HbA1c浓度随葡萄糖浓度成比例增加。对于重复测量,变异系数(CV)为4.08%(范围为1.16 - 6.10%)。样本在4°C下可稳定保存5天。该检测方法在评估范围内呈线性。肝素抗凝和EDTA抗凝血液提供了可比的结果。HbA1c的参考区间为9 - 18.5毫摩尔/摩尔。年龄或品种对HbA1c无明显影响。在糖尿病犬中,HbA1c范围为14至48毫摩尔/摩尔。

结论

该检测方法为犬HbA1c测量提供了一种可靠的方法,具有良好的分析性能。