Vernet P, Durry A, Nicolau X, D'Ambrosio A, Collinet A, Botero Salazar S, Liverneaux P, Hidalgo Diaz J J
Department of Hand Surgery, SOS main, CCOM, University Hospital of Strasbourg, FMTS, University of Strasbourg, Icube CNRS 7357, 10, avenue Baumann, 67400 Illkirch, France.
Department of Hand Surgery, SOS main, CCOM, University Hospital of Strasbourg, FMTS, University of Strasbourg, Icube CNRS 7357, 10, avenue Baumann, 67400 Illkirch, France.
Orthop Traumatol Surg Res. 2017 Oct;103(6):911-913. doi: 10.1016/j.otsr.2017.04.001. Epub 2017 Apr 15.
Osteosynthesis of the distal radius by a volar plate can be complicated by lesions of extensor tendons by screws penetrating the dorsal cortex. The fluoroscopic skyline view enables to confirm the length of the screws. To avoid its risk of irradiation, some authors have recommended using ultrasound instead.
The goal of this study was to demonstrate that the detection rate of screws penetrating the dorsal cortex was at least as good using ultrasound compared to fluoroscopic skyline. A volar plate in which one screw penetrated the dorsal cortex was implanted in 10 cadaveric wrists. Three observers had to detect which screw penetrated the dorsal cortex using ultrasound and then a fluoroscopic skyline.
The detection rate of screws penetrating the dorsal cortex was 43.33% with ultrasound and 96.97% using the fluoroscopic skyline. Agreement between the observers was poor with ultrasound and good with fluoroscopy.
Our results show that ultrasound cannot replace the fluoroscopic skyline view to detect screws penetrating the dorsal cortex of the distal radius in clinical practice.
II.
使用掌侧钢板对桡骨远端进行骨合成时,可能会因螺钉穿透背侧皮质而导致伸肌腱损伤。透视下的天际线视图能够确认螺钉的长度。为避免辐射风险,一些作者建议改用超声检查。
本研究的目的是证明,与透视下的天际线视图相比,使用超声检测螺钉穿透背侧皮质的检出率至少相同。将一枚螺钉穿透背侧皮质的掌侧钢板植入10具尸体手腕中。三名观察者必须先用超声,然后用透视下的天际线视图来检测哪枚螺钉穿透了背侧皮质。
使用超声检测螺钉穿透背侧皮质的检出率为43.33%,而使用透视下的天际线视图时为96.97%。观察者之间使用超声时的一致性较差,而使用透视检查时一致性良好。
我们的结果表明,在临床实践中,超声无法替代透视下的天际线视图来检测穿透桡骨远端背侧皮质的螺钉。
II级。