Suppr超能文献

用于大鼠周围神经缝合的高清视频系统

High-Definition Video System for Peripheral Neurorrhaphy in Rats.

作者信息

Monteiro de Barros Rui Sergio, Brito Marcus Vinicius Henriques, Teixeira Renan Kleber Costa, Yamaki Vitor Nagai, Costa Felipe Lobato da Silva, Sabbá Marcelo Ferreia, Lemos Marcos Vinicius Vieira, Parente Igor Costa, Feijó Daniel Haber

机构信息

1 State University of Pará, Belém, Brazil.

出版信息

Surg Innov. 2017 Aug;24(4):369-372. doi: 10.1177/1553350617704755. Epub 2017 Apr 24.

Abstract

BACKGROUND

Although all microsurgeries are based on the use of surgical microscopes, several alternative magnification systems have shown promising results. Improvements in image quality facilitated the use of video systems in microsurgeries with safety and accuracy. The aim of this study was to evaluate the use of a low-cost, video-assisted magnification system in peripheral neurorrhaphy in rats.

METHODS

Twenty Wistar rats were randomly divided into 2 matched groups according to the magnification system used: the microscope group, with neurorrhaphy performed under a microscope with an image magnification of 40×; and the video system group, with the procedures performed under a video system composed of a high-definition Sony camcorder DCR-SR42 set to 52× magnification, macro lenses, 42-inch television, and a digital HDMI cable. We analyzed weight, nerve caliber, total surgery time, neurorrhaphy time, number of stitches, and number of axons in both ends (proximal and distal).

RESULTS

There were no significant differences between groups in weight, nerve caliber, or number of stitches. Neurorrhaphy under the video system took longer (video: 5.60 minutes; microscope: 3.20 minutes; P < .05). Number of axons was similar between groups, both in proximal and distal stumps.

CONCLUSION

It is possible to perform a peripheral neurorrhaphy in rats through video system magnification, but with a longer surgical time.

摘要

背景

尽管所有显微手术都基于手术显微镜的使用,但几种替代放大系统已显示出有前景的结果。图像质量的提高促进了视频系统在显微手术中的安全且准确的应用。本研究的目的是评估一种低成本的视频辅助放大系统在大鼠周围神经缝合术中的应用。

方法

根据所使用的放大系统,将20只Wistar大鼠随机分为2个匹配组:显微镜组,在图像放大倍数为40倍的显微镜下进行神经缝合;视频系统组,手术在由高清索尼摄像机DCR - SR42(设置为52倍放大)、微距镜头、42英寸电视和数字HDMI线组成的视频系统下进行。我们分析了两组的体重、神经直径、总手术时间、神经缝合时间、缝合针数以及两端(近端和远端)的轴突数量。

结果

两组在体重、神经直径或缝合针数方面无显著差异。视频系统下的神经缝合时间更长(视频组:5.60分钟;显微镜组:3.20分钟;P <.05)。两组近端和远端残端的轴突数量相似。

结论

通过视频系统放大在大鼠中进行周围神经缝合是可行的,但手术时间更长。