To qualitatively analyse the evolution of filtering blebs after XEN surgery, by using anterior segment optical coherence tomography (AS-OCT).
A prospective study was performed on filtering blebs of 30 eyes with cataracts and glaucoma, surgically operated on using phacoemulsification and XEN45 implantation (PHACO-XEN). AS-OCT was used to analyse bleb morphology and reflectivity at 3, 6, and 12 months after surgery. Functionality was studied considering an intraocular pressure (IOP)≤18mmHg without antihypertensive medication.
The IOP enabled the blebs to be classified into non-functional: flat (6.67%) and encapsulated (3.33%); and functional (90%), which were then divide by their morphology into cystic (5/27), diffuse (2/27), and layered (20/27). Cystic types had a mean IOP of 12.8, 12.6, and 14.0mmHg at 3, 6 and 12 months, respectively. In the diffuse type, the mean IOP was 13.0, 11.5 and 13.0mmHg at 3, 6 and 12 months, respectively. In the layers pattern the mean IOP was 14.45, 14.55 and 14.8mmHg at 3, 6 and 12 months respectively. The percentage of blebs with high reflectivity was 48.15%, 62.96%, and 77.78%, at 3, 6 and 12 months, with a mean IOP of 14.23, 14.59, and 15.14mmHg in each time period, respectively.
AS-OCT could be a good predictor of bleb functionality in PHACO-XEN surgery. Those with a cystic pattern or low reflectivity seem to have better post-operative success. Nevertheless, more long-term studies are required.
通过使用眼前节光学相干断层扫描(AS-OCT)对XEN手术后视滤过泡的演变进行定性分析。
对30例患有白内障和青光眼的眼睛的滤过泡进行前瞻性研究,采用超声乳化和XEN45植入术(PHACO-XEN)进行手术。使用AS-OCT分析术后3、6和12个月时滤过泡的形态和反射率。在未使用抗高血压药物的情况下,若眼压(IOP)≤18mmHg,则研究滤过泡的功能。
根据眼压可将滤过泡分为无功能型:扁平型(6.67%)和包裹型(3.33%);以及功能型(90%),然后根据其形态将功能型滤过泡分为囊状(5/27)、弥漫型(2/27)和层状(20/27)。囊状滤过泡在3、6和12个月时的平均眼压分别为12.8、12.6和14.0mmHg。弥漫型滤过泡在3、6和12个月时的平均眼压分别为13.0、11.5和13.0mmHg。层状滤过泡在3、6和12个月时的平均眼压分别为14.45、14.55和14.8mmHg。在3、6和12个月时,高反射率滤过泡的百分比分别为48.15%、62.96%和77.78%,各时间段的平均眼压分别为14.23、14.59和15.14mmHg。