Acta Biomed. 2017 Apr 28;88(1):49-56. doi: 10.23750/abm.v88i1.5285.

Abstract

OBJECTIVE

the purpose of this study was to offer an example of evaluations of the ISO9001 certified internal quality assurance (QA) system of 99mTc-radiopharmaceutical preparations and quality control in vivo use, using industrial kits and generators in order to identify possible sources of errors in the procedures labeling and quality control procedures.

METHODS

The study was performed at a single institution over a period of three years (July 1st, 2011 - July 1st, 2014), and included a total of 2280 radiopharmaceutical preparations prepared by four different technologists. All the radiopharmaceutical preparations and quality controls were performed according to each SPC provided by the manufacturer. The radiopharmaceutical preparations were the following (trade names are reported in brackets): 99mTc-albumin colloid [Nanocoll] (n=349), 99mTc-oxidronate [Technescan®hdp] (n=701), 99mTc-exametazime [Ceretec] (n=169), 99mTc-sestamibi [Cardiolite] (n=92), 99mTc-albumin aggregated [Technescan®lyomaa] (n=140), 99mTc-tetrofosmin [Myoview]) (n=567), 99mTc-diethylene triamine pentacetic acid [Technescan®dtpa] (n=254), and 99mTc-dimercapto succinic acid [Renocis®] (n=8). Data were analyzed to determine the number and type of radiopharmaceutical labelling failure and to derive the sources of these failures to define corrective actions and optimize the quality assurance program.

RESULTS

A total of 2280 procedures were performed and recorded. Following the quality control procedure six out of the 2280 preparations (0.26%) were non-conforming for clinical use with the RCP limits indicated in the SPC. Five of these were due to gross technical errors in measurements and manual procedures and were immediately repeated, returning within the limits of acceptability. The sixth failure was due to short incubation time, though compliant with the manufacturer's instructions.

CONCLUSIONS

We concluded that the quality of the final product depends on a controlled production system based on the implementation of specific standard operating procedures (ISO9001, SOP) for each radiopharmaceutical production, according to strict adherence to the SPC of each radiopharmaceutical. Based on these conclusions, in our opinion every quality control suggesting a possible error in the synthesis procedure recommended in the SPC should be immediately reported to the manufacturer, for a revision of the SPC, as well as to the regulatory agencies for an alert. This strategy may in fact allow the continuous improvement of the labelling procedures and therefore the optimization of the quality control procedures frequency to ensure both patients safety and a more rational management of resources for economic sustainability.

摘要

目的

本研究旨在提供一个对采用工业试剂盒和发生器的99mTc放射性药物制剂的ISO9001认证内部质量保证(QA)体系及体内使用质量控制进行评估的示例,以识别程序标记和质量控制程序中可能的误差来源。

方法

本研究在一家机构内进行,为期三年(2011年7月1日至2014年7月1日),共纳入由四名不同技术人员制备的2280份放射性药物制剂。所有放射性药物制剂和质量控制均按照制造商提供的各SPC进行。放射性药物制剂如下(括号内为商品名):99mTc - 白蛋白胶体[纳米胶体](n = 349)、99mTc - 奥昔膦酸盐[锝迈德®hdp](n = 701)、99mTc - 依沙美肟[脑显肽](n = 169)、99mTc - 司他比[心肌显像剂](n = 92)、99mTc - 聚合白蛋白[锝迈德®lyomaa](n = 140)、99mTc - 替曲膦[迈威显](n = 567)、99mTc - 二乙三胺五乙酸[锝迈德®dtpa](n = 254)以及99mTc - 二巯基丁二酸[肾显](n = 8)。对数据进行分析,以确定放射性药物标记失败的数量和类型,并找出这些失败的来源,从而确定纠正措施并优化质量保证计划。

结果

共执行并记录了2280个程序。按照质量控制程序,2280份制剂中有6份(0.26%)不符合SPC中规定的临床使用RCP限值。其中5份是由于测量和手动操作中的重大技术错误,随即重新进行,结果在可接受范围内。第六次失败是由于孵育时间短,尽管符合制造商的说明。

结论

我们得出结论,最终产品的质量取决于基于为每种放射性药物生产实施特定标准操作规程(ISO9001,SOP)的受控生产系统,严格遵守每种放射性药物的SPC。基于这些结论,我们认为,每一项表明SPC中推荐的合成程序可能存在误差的质量控制结果都应立即报告给制造商,以便修订SPC,同时报告给监管机构以发出警示。事实上,这种策略可能会使标记程序不断改进,从而优化质量控制程序的频率,以确保患者安全并更合理地管理资源以实现经济可持续性。