Ponto J A
Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City 52242, USA.
J Nucl Med Technol. 1998 Dec;26(4):262-4.
Chemical reactions involved in preparing 99mTc radiopharmaceuticals occasionally result in products of substandard purity. A retrospective examination of preparation problems that occurred in the author's institution was conducted to better define the incidence, recognize patterns and identify causes of substandard 99mTc radiopharmaceutical products.
All 99mTc radiopharmaceutical preparation and quality control testing records for the years 1986-1997 were reviewed, and preparation factors associated with substandard products were identified and examined.
Fifty of 20,972 (0.2%) 99mTc products had substandard radiochemical purity; none were administered to patients. Twenty-eight of the 50 substandard products (56%) involved macroaggregated albumin with the remainder divided among in vitro red blood cells, exametazime, disofenin, sestamibi, mertiatide and sulfur colloid. Thirty-three of the 50 (66%) involved 99mTc-pertechnetate obtained as the first elution of a new generator and/or 99mTc-pertechnetate more than 12 hr old. Several of the substandard products involved other preparation factors and/or human error.
The majority of substandard 99mTc radiopharmaceutical products involved the use of 99mTc-pertechnetate containing excessive amounts of 99Tc and/or oxidizing impurities to prepare products containing relatively small amounts of stannous. Although substandard products are an infrequent occurrence, radiochemical purity testing should be performed routinely on all 99mTc radiopharmaceuticals before patient administration.
制备99mTc放射性药物所涉及的化学反应偶尔会产生纯度不达标的产品。对作者所在机构发生的制备问题进行回顾性检查,以更好地确定不合格99mTc放射性药物产品的发生率、识别模式并找出原因。
回顾了1986 - 1997年所有99mTc放射性药物的制备和质量控制测试记录,确定并检查了与不合格产品相关的制备因素。
在20972个99mTc产品中有50个(0.2%)放射化学纯度不合格;无一用于患者。50个不合格产品中有28个(56%)涉及大颗粒白蛋白,其余分布在体外红细胞、依沙美肟、二膦酸盐、司他米比、美替肽和硫胶体中。50个中有33个(66%)涉及作为新发生器首次洗脱获得的99mTc高锝酸盐和/或超过12小时的99mTc高锝酸盐。一些不合格产品涉及其他制备因素和/或人为错误。
大多数不合格的99mTc放射性药物产品涉及使用含有过量99Tc和/或氧化性杂质的99mTc高锝酸盐来制备含锡量相对较少的产品。尽管不合格产品很少出现,但在给患者使用前,应对所有99mTc放射性药物常规进行放射化学纯度检测。