Abstract

The influence of effective room temperature on the radiochemical purity of Tc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the Tc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the Tc-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 Tc-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 °C, the temperature, in general, required for the preparation and storage of Tc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration.

摘要

报道了有效室温对 Tc 放射性药物放射化学纯度的影响。这项研究源于这样一种观察,即在用于制备 Tc 放射性药物的隔离器中,温度可能高于试剂盒商业说明性插页中报告的温度。这主要是由于工作区域小、存在加热仪器、空气过滤的持续激活,以及用于制备和储存 Tc 放射性药物的隔离器的环境完全隔离且未调节。总共测试了 244 种 Tc 放射性药物制剂(七种不同类型),并在制备结束时和有效期内检查了放射化学纯度。此外,我们发现隔离器内的平均温度明显高于 25°C,这是一般情况下制备和储存 Tc 放射性药物所需的温度。结果证实了放射性药物产品的放射化学稳定性。然而,正如质量保证领域所要求的那样,在进行人体给药之前,必须验证制造商要求以外的条件对放射性药物质量的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1371/6017376/6b9aa1d95403/molecules-23-00661-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验