Suppr超能文献

双频压电内镜换能器用于成像胰腺癌血管侵犯。

Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

出版信息

IEEE Trans Ultrason Ferroelectr Freq Control. 2017 Jul;64(7):1078-1086. doi: 10.1109/TUFFC.2017.2702010. Epub 2017 May 8.

Abstract

Cancers of the pancreas have the poorest prognosis among all cancers, as many tumors are not detected until surgery is no longer a viable option. Surgical viability is typically determined via endoscopic ultrasound imaging. However, many patients who may be eligible for resection are not offered surgery due to diagnostic challenges in determining vascular or lymphatic invasion. In this paper, we describe the development of a dual-frequency piezoelectric transducer for rotational endoscopic imaging designed to transmit at 4 MHz and receive at 20 MHz in order to image microbubble-specific superharmonic signals. Imaging performance is assessed in a tissue-mimicking phantom at depths from 1 cm [contrast-to-tissue ratio (CTR) = 21.6 dB] to 2.5 cm (CTR = 11.4 dB), in ex vivo porcine vessels, and in vivo in a rodent. The prototyped 1.1-mm aperture transducer demonstrates contrast-specific imaging of microbubbles in a 200- [Formula: see text]-diameter tube through the wall of a 1-cm-diameter porcine artery, suggesting such a device may enable direct visualization of small vessels from within the lumen of larger vessels such as the portal vein or superior mesenteric vein.

摘要

胰腺癌症是所有癌症中预后最差的,因为许多肿瘤直到手术不再可行时才被发现。手术的可行性通常通过内镜超声成像来确定。然而,许多有资格接受切除术的患者由于在确定血管或淋巴侵犯方面存在诊断挑战而未接受手术。在本文中,我们描述了一种用于旋转式内镜成像的双频压电换能器的开发,该换能器旨在以 4 MHz 发射和以 20 MHz 接收,以对微泡特异性的超谐波信号进行成像。在从 1 厘米深(对比组织比 [CTR] = 21.6 dB)到 2.5 厘米深(CTR = 11.4 dB)的组织模拟体模、离体猪血管和体内啮齿动物中评估了成像性能。原型 1.1 毫米孔径换能器通过 1 厘米直径猪动脉壁上的 200-[公式:见正文]-直径管对微泡进行了对比度特异性成像,这表明这种设备可能能够直接从门静脉或肠系膜上静脉等较大血管的管腔内可视化小血管。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8d43/5568756/bf72a25f3568/nihms896222f1.jpg

相似文献

1
Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.双频压电内镜换能器用于成像胰腺癌血管侵犯。
IEEE Trans Ultrason Ferroelectr Freq Control. 2017 Jul;64(7):1078-1086. doi: 10.1109/TUFFC.2017.2702010. Epub 2017 May 8.
5
Characterization of an Array-Based Dual-Frequency Transducer for Superharmonic Contrast Imaging.基于阵列的双频换能器用于二次谐波对比成像的特性分析。
IEEE Trans Ultrason Ferroelectr Freq Control. 2021 Jul;68(7):2419-2431. doi: 10.1109/TUFFC.2021.3065952. Epub 2021 Jun 29.
9
Nonlinear intravascular ultrasound contrast imaging.非线性血管内超声造影成像
Ultrasound Med Biol. 2006 Apr;32(4):491-502. doi: 10.1016/j.ultrasmedbio.2006.01.001.

引用本文的文献

本文引用的文献

7
Design, Fabrication, and Characterization of a Bifrequency Colinear Array.双频共线阵列的设计、制造与表征
IEEE Trans Ultrason Ferroelectr Freq Control. 2016 Feb;63(2):266-74. doi: 10.1109/TUFFC.2015.2506000. Epub 2015 Dec 4.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验