Suppr超能文献

直肠癌:3.0T磁共振成像中体素内不相干运动参数的短期可重复性

Rectal cancer: Short-term reproducibility of intravoxel incoherent motion parameters in 3.0T magnetic resonance imaging.

作者信息

Sun Hongliang, Xu Yanyan, Xu Qiaoyu, Shi Kaining, Wang Wu

机构信息

Department of Radiology, China-Japan Friendship Hospital, Chaoyang District Philips Healthcare, Beijing, China.

出版信息

Medicine (Baltimore). 2017 May;96(19):e6866. doi: 10.1097/MD.0000000000006866.

Abstract

The aim of this study was to evaluate the short-term test-retest reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) parameters of rectal cancer with 3.0T MRI.Twenty-six patients with rectal cancer underwent MRI, including diffusion-weighted imaging with 8 b values. Apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM) parameters (D, pure diffusion; f, perfusion fraction; D*, pseudodiffusion coefficient) were, respectively, calculated. The short-term test-retest reproducibility, the intra and interobserver variation of the IVIM parameters were assessed based on the repeatability coefficient and Bland-Altman limits of agreement.There was no significant intra or interobserver difference observed in the parameters on the same DW-MRI scan. The corresponding repeatability coefficient of intra- and interobserver analysis for ADC, D, f, and D* was 5.4%, 11.1%, 55.4%, and 40.3%; 10.9%, 41.6%, 134.0%, and 177.6%, respectively. The test-retest repeatability coefficient for ADC, D, f, and D* was 19.1%, 24.5%, 126.3%, and 197.4%, respectively, greater than the intraobserver values.ADC and D have better short-term test-retest reproducibility than f and D*. Considering the poor test-retest reproducibility for f and D,* variance in these 2 parameters should be interpreted with caution in longitudinal studies on rectal cancer in which treatment response and recurrence are monitored.

摘要

本研究的目的是利用3.0T磁共振成像评估直肠癌扩散加权磁共振成像(DW-MRI)参数的短期重测可重复性。26例直肠癌患者接受了MRI检查,包括具有8个b值的扩散加权成像。分别计算表观扩散系数(ADC)和体素内不相干运动(IVIM)参数(D,纯扩散;f,灌注分数;D*,伪扩散系数)。基于可重复性系数和Bland-Altman一致性界限评估IVIM参数的短期重测可重复性、观察者内和观察者间变异。在同一DW-MRI扫描的参数中未观察到显著的观察者内或观察者间差异。ADC、D、f和D的观察者内和观察者间分析的相应可重复性系数分别为5.4%、11.1%、55.4%和40.3%;10.9%、41.6%、134.0%和177.6%。ADC、D、f和D的重测可重复性系数分别为19.1%、24.5%、126.3%和197.4%,均大于观察者内值。ADC和D的短期重测可重复性优于f和D*。考虑到f和D*的重测可重复性较差,在监测直肠癌治疗反应和复发的纵向研究中,对这两个参数的差异应谨慎解释。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dea0/5428618/52b9840d83a9/medi-96-e6866-g005.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验