Suppr超能文献

使用MediGuide非透视导管跟踪系统进行心房颤动消融:一种减少辐射暴露的新技术。

Atrial Flutter Ablation Using MediGuide Non-fluoroscopic Catheter Tracking System: A Novel Technology to Reduce Radiation Exposure.

作者信息

Pillai Anand, Reddy Madhu, Heard Michael, Vallakati Ajay, Berenbom Loren, Lakkireddy Dhanunjaya

机构信息

Section of Electrophysiology, Bloch Heart Rhythm Center, University of Kansas Hospital, Kansas City, KS.

St. Jude Medical, Kansas City, KS.

出版信息

J Atr Fibrillation. 2012 Oct 6;5(3):730. doi: 10.4022/jafib.730. eCollection 2012 Oct-Nov.

Abstract

We describe the first case of cardiac arrhythmia ablation with the novel MediGuide non-fluoroscopic catheter tracking system in North America. This new technology uses electromagnetic field to track sensor integrated intracardiac electrophysiology catheters which are projected on pre-recorded fluoroscopy cine loops. This new technology permits catheter tracking in virtual biplane fluoroscopy and enhances spatial resolution of conventional 3D mapping systems while drastically reducing radiation exposure.

摘要

我们描述了北美首例使用新型MediGuide非荧光透视导管追踪系统进行心律失常消融的病例。这项新技术利用电磁场追踪集成了传感器的心内电生理导管,这些导管被投射到预先录制的荧光透视电影环上。这项新技术允许在虚拟双平面荧光透视中追踪导管,并提高传统三维标测系统的空间分辨率,同时大幅减少辐射暴露。

相似文献

1
Atrial Flutter Ablation Using MediGuide Non-fluoroscopic Catheter Tracking System: A Novel Technology to Reduce Radiation Exposure.
J Atr Fibrillation. 2012 Oct 6;5(3):730. doi: 10.4022/jafib.730. eCollection 2012 Oct-Nov.
2
Ablation of typical atrial flutter using the novel MediGuide 3D catheter tracking system: a review of the literature.
Expert Rev Cardiovasc Ther. 2014 Jul;12(7):799-802. doi: 10.1586/14779072.2014.925801. Epub 2014 Jun 5.
3
Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system.
Europace. 2013 Apr;15(4):578-81. doi: 10.1093/europace/eus226. Epub 2012 Aug 2.
4
Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.
Circ Arrhythm Electrophysiol. 2012 Aug 1;5(4):684-90. doi: 10.1161/CIRCEP.112.971705. Epub 2012 Jul 7.
5
MediGuide in supraventricular tachycardia: initial experience from a multicentre registry.
Europace. 2013 Sep;15(9):1292-7. doi: 10.1093/europace/eut090. Epub 2013 Apr 23.
6
Catheter ablation of atrial fibrillation supported by novel nonfluoroscopic 4D navigation technology.
Heart Rhythm. 2013 Sep;10(9):1293-300. doi: 10.1016/j.hrthm.2013.05.008. Epub 2013 May 14.
8
MediGuide-impact on catheter ablation techniques and workflow.
J Interv Card Electrophysiol. 2014 Sep;40(3):221-7. doi: 10.1007/s10840-014-9909-8. Epub 2014 Jun 14.
9
Sensor-Based Electromagnetic Navigation (Mediguide®): How Accurate Is It? A Phantom Model Study.
J Cardiovasc Electrophysiol. 2015 Oct;26(10):1140-5. doi: 10.1111/jce.12741. Epub 2015 Jul 27.
10
The Unique MediGuide Technology For CRT Lead Placement And Catheter Ablation.
J Atr Fibrillation. 2014 Jun 30;7(1):1072. doi: 10.4022/jafib.1072. eCollection 2014 Jun-Jul.

引用本文的文献

1
Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization-a prospective randomized comparison.
J Interv Card Electrophysiol. 2019 Jan;54(1):35-42. doi: 10.1007/s10840-018-0446-8. Epub 2018 Sep 18.

本文引用的文献

1
Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system.
Europace. 2013 Apr;15(4):578-81. doi: 10.1093/europace/eus226. Epub 2012 Aug 2.
2
Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.
Circ Arrhythm Electrophysiol. 2011 Aug;4(4):e36-8. doi: 10.1161/CIRCEP.111.962225.
3
Electromagnetic navigation for percutaneous guide-wire insertion: accuracy and efficiency compared to conventional fluoroscopic guidance.
Neuroimage. 2009 Aug;47 Suppl 2:T127-32. doi: 10.1016/j.neuroimage.2009.05.002. Epub 2009 May 7.
4
Impact of a comprehensive safety program on radiation exposure during catheter ablation of atrial fibrillation: a prospective study.
J Interv Card Electrophysiol. 2009 Mar;24(2):105-12. doi: 10.1007/s10840-008-9316-0. Epub 2008 Nov 6.
5
Cumulative patient effective dose in cardiology.
Br J Radiol. 2008 Sep;81(969):699-705. doi: 10.1259/bjr/29507259. Epub 2008 May 28.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验