Suppr超能文献

海报 - 周四晚上 - 47:用于调试和患者特定质量保证的ArcCHECK设备评估

Poster - Thur Eve - 47: Evaluation of the ArcCHECK device for commissioning and patient-specific QA.

作者信息

Shahine B, Badragan I, Ramaseshan R

机构信息

BC Cancer Agency - Abbotsford Centre, Abbotsford, BC, Canada.

出版信息

Med Phys. 2012 Jul;39(7Part3):4633. doi: 10.1118/1.4740155.

Abstract

The most promising method of accurately verifying VMAT treatments is by direct dose measurement over the three dimensions of irradiated volume. ArcCHECK device (Sun Nuclear, Melbourne, FL) have the potential to detect delivery errors on the treatment machine due to mechanical problems resulting from gantry and MLC motion. The estimation of the dosimetric leaf gap (DLG) parameter for Varian MLC (Varian Medical Systems, Palo Alto, CA) was attempted using ArcCHECK. Finding the optimal DLG value for use in TPS requires a measuring device like ArcCHECK to be employed especially in highly intensity modulated fields. In addition, ArcCHECK was used to assess the effect of positional error of MLC leaf in a given VMAT plan. Patient-specific QA tests were performed using the ArcCHECK device. QA results of patient plans that failed considering portal dosimetry technique were reassessed with ArcCHECK measurements for IMRT plans. The preliminary test results and performance of the ArcCHECK device were very encouraging. VMAT plans for head and neck cases were generated and their delivery was evaluated using ArcCHECK. Results have shown a success rate greater than 90% in the quality assurance of individual plans. Optimal DLG value was detected using ArcCHECK. Also, the device showed enough sensitivity to identify failed QA plans. Moreover, MLC central leaf pair position offset in a VMAT plan of the order of 1mm was fairly distinguished by ArcCHECK measurements.

摘要

准确验证容积调强弧形放疗(VMAT)治疗的最有前景的方法是在照射体积的三个维度上进行直接剂量测量。ArcCHECK设备(美国佛罗里达州墨尔本的Sun Nuclear公司)有潜力检测治疗机上由于机架和多叶准直器(MLC)运动导致的机械问题所引起的剂量输送误差。尝试使用ArcCHECK对瓦里安MLC(美国加利福尼亚州帕洛阿尔托的瓦里安医疗系统公司)的剂量学叶片间隙(DLG)参数进行估计。要找到用于治疗计划系统(TPS)的最佳DLG值,需要使用像ArcCHECK这样的测量设备,尤其是在高剂量强度调制野中。此外,ArcCHECK被用于评估在给定的VMAT计划中MLC叶片位置误差的影响。使用ArcCHECK设备进行了针对患者的质量保证(QA)测试。对于那些考虑了射野剂量测定技术却不合格的患者计划的QA结果,用ArcCHECK对调强放疗(IMRT)计划的测量进行了重新评估。ArcCHECK设备的初步测试结果和性能非常令人鼓舞。生成了头颈部病例的VMAT计划,并使用ArcCHECK对其执行情况进行了评估。结果表明,单个计划的质量保证成功率大于90%。使用ArcCHECK检测到了最佳DLG值。而且,该设备显示出足够的灵敏度来识别不合格的QA计划。此外,通过ArcCHECK测量能相当明显地区分VMAT计划中MLC中央叶片对1毫米量级的位置偏移。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验