Yao Li-Ping, Zhang Li, Li Hui-Ming, Ding Ming, Yu Ling-Wei, Yang Xin, Li Xiao-Ming, Sun Kun
Biomedical Engineering Institution Affiliated to Shanghai Jiaotong University, No. 1954 Hua-Shan Road, Xuhui District, Shanghai, 200030, China.
Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092, China.
Int J Cardiovasc Imaging. 2017 Dec;33(12):2021-2028. doi: 10.1007/s10554-017-1150-y. Epub 2017 May 18.
This study aims to investigate the imaging quality and radiation dose of prospective ECG-triggered 256 multi-slice computer tomography (MSCT) in accessing the coronary artery (CA) in children. Coronary arteries of 149 children were evaluated using prospective ECG-triggered 256 MSCT with the same system settings. A four-point scoring system was applied to study the capability of MSCT in detecting CA in these patients. Signal, noise and contrast-to-noise ratios (CNR) were analyzed to investigate the association of image quality with age. Then, volumetric CT dose index (CTDI), dose-length product (DLP), and effective dose (ED) were utilized to study the association of radiation dose with age. The detection rate for original, proximal, middle, distal and the 11 segments of CA was 100, 97, 92, 81 and 92%, respectively; and there was no influence on age during the detection (all, P < 0.05). A negative correlation was found between ED and age (r = -0.664, P < 0.001). Significantly larger EDs were found in younger patients (age: <3 years; 1.2 ± 0.5 and 0.6 ± 0.2 mSv; P < 0.001), while higher DLPs were found in elder patients, although no correlation was found between ages versus DLP (r = 0.092, P = 0.262). Prospective ECG-triggered 256 MSCT has considerable performance for the evaluation of CA in children. However, great caution is needed for children under the age of three in the selection of this examination. Furthermore, the tube current could be further reduced for the examination of children ≥8 years.
本研究旨在探讨前瞻性心电图触发的256层螺旋计算机断层扫描(MSCT)在评估儿童冠状动脉(CA)时的成像质量和辐射剂量。使用具有相同系统设置的前瞻性心电图触发256层MSCT对149例儿童的冠状动脉进行评估。应用四点评分系统研究MSCT在这些患者中检测CA的能力。分析信号、噪声和对比噪声比(CNR)以研究图像质量与年龄的关系。然后,利用容积CT剂量指数(CTDI)、剂量长度乘积(DLP)和有效剂量(ED)研究辐射剂量与年龄的关系。CA原始段、近端段、中段、远端段及11个节段的检出率分别为100%、97%、92%、81%和92%;检测过程中年龄无影响(均P<0.05)。ED与年龄呈负相关(r=-0.664,P<0.001)。较年轻患者(年龄:<3岁;1.2±0.5和0.6±0.2 mSv;P<0.001)的ED明显更高,而老年患者的DLP更高,尽管年龄与DLP之间未发现相关性(r=0.092,P=0.262)。前瞻性心电图触发256层MSCT在评估儿童CA方面具有相当好的性能。然而,对于三岁以下儿童,在选择此项检查时需要格外谨慎。此外,对于8岁及以上儿童的检查,管电流可进一步降低。